птфе трубы
-
PTFE капиллярные 0,05 мм тонкостенные малые трубки OEM производитель
Precision Small-Bore PTFE Tubing for Fluid Handling, Instrumentation and Industrial Applications
Yozonetech PTFE Capillary Tube is a precision small-bore tubing solution manufactured from high-performance PTFE. Designed for applications where compact dimensions, low friction, chemical resistance, electrical insulation, and dimensional consistency are important, PTFE capillary tubing provides a reliable fluid or cable pathway in demanding environments.
Compared with conventional PTFE tubing, capillary tubing is designed around smaller internal diameters and more precise dimensional requirements. It is widely used in analytical instruments, laboratory equipment, chemical dosing systems, pneumatic control, medical equipment, semiconductor equipment, electrical applications, and other systems requiring small-diameter tubing.
Yozonetech manufactures PTFE capillary tubing in a wide range of AWG-based sizes, with typical internal diameters from approximately 0.25 mm to 8.69 mm. Different S-Type, T-Type, and L-Type outside diameters are available for many sizes, allowing engineers to select the appropriate wall configuration according to their application.
Custom ID, OD, wall thickness, length, packaging, and other specifications can also be discussed according to project requirements.
Основные характеристики
- Small Internal Diameters — Designed for small-bore applications where conventional tubing may be too large.
- Excellent Chemical Resistance — PTFE resists many chemicals, solvents, acids, bases, and aggressive media.
- Low Friction — The naturally low coefficient of friction helps reduce resistance to fluid movement and component insertion.
- High Temperature Resistance — PTFE provides excellent thermal stability for demanding temperature environments.
- Excellent Electrical Insulation — Suitable for wires, cables, sensors, and electrical component protection.
- Smooth Inner Surface — Helps reduce friction during fluid movement or insertion of wires and components.
- Dimensional Options — Multiple OD configurations are available for many AWG sizes.
- Custom Manufacturing — Custom ID, OD, wall thickness, tolerance, length, and packaging can be discussed.
PTFE Capillary Tube Specifications
AWG ID Min. (mm) ID Normal (mm) ID Max. (mm) S-Type OD (mm) T-Type OD (mm) L-Type OD (mm) Package (m) 30 0.25 0.30 0.38 0.76 0.76 0.60 305 28 0.33 0.38 0.46 0.84 0.84 0.68 305 26 0.41 0.46 0.53 0.92 0.92 0.76 305 24 0.51 0.56 0.66 1.16 1.06 0.86 305 23 0.58 0.66 0.74 1.26 1.16 0.96 305 22 0.66 0.71 0.81 1.31 1.21 1.01 305 21 0.74 0.81 0.89 1.41 1.31 1.11 305 20 0.81 0.86 0.97 1.66 1.46 1.16 305 19 0.91 0.96 1.07 1.76 1.56 1.26 305 18 1.01 1.07 1.17 1.87 1.67 1.37 305 17 1.14 1.19 1.32 1.99 1.79 1.49 305 16 1.29 1.34 1.47 2.14 1.94 1.64 305 15 1.45 1.50 1.65 2.30 2.10 1.80 153 14 1.62 1.68 1.83 2.48 2.28 2.08 153 13 1.83 1.93 2.05 2.73 2.53 2.33 153 12 2.05 2.16 2.31 2.96 2.77 2.56 153 11 2.31 2.41 2.57 3.21 3.01 2.81 153 10 2.59 2.69 2.84 3.49 3.29 3.09 153 9 2.90 3.00 3.15 4.00 3.76 3.40 100 8 3.28 3.38 3.53 4.38 4.14 3.78 100 7 3.65 3.76 3.94 4.76 4.52 4.16 100 6 4.11 4.22 4.41 5.22 4.98 4.72 100 5 4.62 4.72 4.95 5.72 5.48 6.22* 100 4 5.18 5.28 5.53 6.28 6.04 5.78 100 3 5.81 5.94 6.20 6.94 6.70 6.44 100 2 6.55 6.68 6.93 7.68 7.44 7.18 100 1 7.34 7.46 7.75 8.46 8.22 7.96 100 0 8.26 8.38 8.69 9.38 9.14 8.80 100 Note: Dimensions represent typical manufacturing sizes. Actual tolerances and available configurations should be confirmed according to the selected specification, application, and production requirements.
* The original specification supplied lists 6.22 mm for AWG 5 L-Type OD. Please confirm this value with the production/engineering team before final publication.
S-Type, T-Type and L-Type Configurations
Different outside-diameter configurations allow PTFE capillary tubing to be adapted to different application requirements. A smaller outside diameter can help reduce overall installation space, while a larger wall configuration can provide additional mechanical protection and dimensional stability.
When selecting a capillary tube, engineers should consider:
- Required internal diameter
- Required outside diameter
- Available installation space
- Required wall thickness
- Fluid volume and flow requirements
- Pressure conditions
- Температура
- Chemical exposure
- Electrical insulation requirements
- Bending and routing conditions
For applications where dimensional tolerances are critical, customers are encouraged to provide drawings or detailed specifications so Yozonetech can recommend the most suitable tubing configuration.
Technical Characteristics of PTFE Capillary Tubing
Химическая стойкость
PTFE is one of the most chemically resistant engineering polymers available. PTFE capillary tubing can be used with many aggressive chemicals, solvents, corrosive fluids, and process media. This makes it particularly useful for laboratory instruments, chemical processing, analytical systems, and semiconductor-related equipment. Actual compatibility should always be evaluated against the specific chemical, concentration, temperature, pressure, and exposure time.
Temperature Resistance
PTFE provides excellent thermal stability and is suitable for high-temperature applications compared with many conventional flexible tubing materials. For applications involving continuous high-temperature exposure, thermal cycling, pressure, or mechanical loading, Yozonetech can evaluate the operating conditions and recommend an appropriate specification.
Low Friction
The smooth PTFE surface and naturally low friction characteristics make the tubing suitable for small-volume fluid transfer, wire insertion, cable protection, probe protection, and moving components.
Электрическая изоляция
PTFE has excellent electrical insulating properties and can be used to protect wires, conductors, sensors, and other electrical components in demanding environments.
Сертификаты

PTFE трубка FDA сертификат

PTFE tube REACH certificate

Трубка PTFE Сертификат RoHS
Типовые применения
Analytical Instruments
PTFE capillary tubing is suitable for analytical and laboratory instruments where small internal diameters, chemical resistance, and clean fluid pathways are required. Typical uses include analytical fluid lines, sampling systems, instrument connections, chemical reagent delivery, and laboratory equipment.
Chemical Dosing and Fluid Handling
The small bore allows controlled transport of relatively small quantities of liquids or gases. Typical applications include chemical dosing, reagent delivery, sampling, and small-volume fluid transfer.
Semiconductor Equipment
PTFE capillary tubing can be used in selected semiconductor and electronics manufacturing equipment where chemical resistance, thermal stability, and reliable tubing dimensions are required. For high-purity applications, material grade, cleanliness, packaging, and production environment should be specified according to process requirements.
Medical and Laboratory Equipment
Small-diameter PTFE tubing can be used in equipment requiring chemical resistance, low friction, and stable dimensional performance. The appropriate grade and regulatory requirements should be confirmed according to the intended medical application.
Pneumatic and Instrumentation Systems
Suitable for compact pneumatic and instrumentation systems where small tubing dimensions and low friction are beneficial.
Wire and Sensor Protection
Can be used as an insulating or protective sleeve for wires, sensor elements, thermocouples, and other small components.
How to Select the Right PTFE Capillary Tube
1. Select the Required ID
Determine the required internal diameter according to the fluid, wire, probe, or component that will pass through the tube. For fluid applications, consider the desired flow rate and pressure drop.
2. Select the OD
After determining the ID, select the outside diameter according to available installation space and required wall thickness.
3. Consider Tolerance
If the tube is used in precision instruments, metering systems, connectors, or assemblies with tight dimensional requirements, specify the required ID and OD tolerances.
4. Consider Temperature
The actual operating temperature should include continuous operating temperature, short-term temperature peaks, thermal cycling, and contact with heated components.
5. Check Chemical Compatibility
PTFE has excellent chemical resistance, but compatibility should still be evaluated against the actual chemical and operating conditions.
6. Consider Length and Packaging
Yozonetech supplies different standard package lengths according to size and can discuss customized cut lengths or packaging requirements for OEM projects.
Custom PTFE Capillary Tube Manufacturing
Standard sizes cover many common applications, but not every engineering system uses a standard dimension. Yozonetech can support customized PTFE capillary tubing according to customer drawings, samples, or specifications.
- Custom ID
- Custom OD
- Custom wall thickness
- Custom tolerance
- Custom length
- Special packaging
- Material requirements
- OEM specifications
For a quotation, customers can provide the required ID, OD, length, application, operating temperature, media, pressure, and estimated annual quantity. Providing a drawing or existing sample is recommended when dimensional compatibility is critical.
Quality Control
For precision small-bore tubing, dimensional consistency is especially important because even a small variation in ID or OD can influence assembly, fluid flow, or component compatibility.
- Raw material control
- Extrusion process control
- Dimensional inspection
- ID and OD verification
- Visual inspection
- Length control
- Batch consistency
- Packaging protection
For OEM and customized orders, inspection requirements can be discussed before production.
Why Choose Yozonetech PTFE Capillary Tube?
Yozonetech specializes in high-performance fluoropolymer tubing and engineering plastic components for industrial applications. Our capabilities cover PTFE, FEP, PFA, ETFE, PEEK and other engineering polymer products, allowing customers to evaluate different materials when PTFE is not the only suitable option.
- Small-diameter fluoropolymer tubing
- Custom dimensions
- OEM manufacturing
- Drawing-based production
- Material selection
- Sample support
- Batch production
- Technical communication
Our objective is not simply to supply commodity tubing, but to provide a reliable tubing solution matched to the customer's application and technical requirements.
Frequently Asked Questions
1. What is PTFE capillary tubing?
PTFE capillary tubing is small-bore tubing manufactured from PTFE and designed for applications requiring compact dimensions, chemical resistance, low friction, thermal stability, and electrical insulation.
2. What is the smallest PTFE capillary tube you manufacture?
The typical size list supplied for Yozonetech starts at AWG 30, with an ID range of approximately 0.25–0.38 mm and a normal ID of 0.30 mm.
3. What is the maximum size in the current capillary tube range?
The supplied standard size list extends to AWG 0, with a normal ID of approximately 8.38 mm and a maximum ID of 8.69 mm.
4. What is the difference between PTFE capillary tube and standard PTFE tube?
PTFE capillary tubing focuses on smaller internal diameters and precision applications. Standard PTFE tubing generally covers a broader range of sizes and applications.
5. Is PTFE capillary tubing suitable for chemicals?
Yes. PTFE has excellent resistance to many acids, bases, solvents, and aggressive chemicals. The actual application should be evaluated based on the specific chemical and operating conditions.
6. Can PTFE capillary tubing be used at high temperatures?
PTFE has excellent high-temperature resistance compared with many conventional tubing materials. The appropriate operating temperature should be evaluated together with pressure and mechanical conditions.
7. Can you manufacture custom PTFE capillary tubing?
Yes. Yozonetech can discuss customized ID, OD, wall thickness, tolerance, length, packaging, and other specifications according to drawings, samples, or engineering requirements.
8. What information should I provide for a quotation?
Ideally provide the required ID, OD, length, tolerance, operating temperature, media, pressure, application, estimated quantity, and any special material or cleanliness requirements.
9. What package lengths are available?
The current standard size list specifies package lengths of 305 m, 153 m, or 100 m depending on the tube size. Customized lengths and packaging can be discussed for specific orders.
10. Can PTFE capillary tubing be used for semiconductor applications?
Yes, PTFE capillary tubing can be used in selected semiconductor equipment and chemical handling applications. For high-purity applications, material grade, cleanliness, packaging, and manufacturing requirements should be confirmed according to the process.
Request a PTFE Capillary Tube Quote
Whether you need a standard AWG size or a custom small-bore PTFE tube, Yozonetech can help evaluate the appropriate specification.
Send us your required ID, OD, length, application, temperature, media, pressure, and quantity, or simply send us your drawing or existing sample.
Our engineering and sales team can review the requirements and recommend a suitable PTFE capillary tubing configuration.
Капилляр Yozonetech PTFE имеет сверхтонкую стенку 0,025 мм, и мы можем заменить ZEUS INC, чтобы стать вашим альтернативным поставщиком.
Капиллярная трубка Yozonetech PTFE будет упакована на катушке для защиты.
Капиллярная трубка Yozonetech PTFE может использоваться в медицинской и пищевой промышленности.
-
PTFE травления трубки OEM производитель для медицинских
Экструзия медицинских трубок Описание товара
Фторопласт часто необходимо смешивать с другими материалами, но из-за его известной гладкой поверхности его трудно соединить с другими материалами. Цель травления фторполимера - изменить характеристики поверхности PTFE, после чего его можно комбинировать с другими материалами, будь то пластик, металл, композитный материал или керамика.
Свойственное фторполимерам сцепление обеспечивает чрезвычайно низкое трение. В неизмененном состоянии связи этих полимеров настолько стабильны, что им трудно соединиться с чем-либо даже на короткий промежуток времени. Когда процесс травления изменяет углеродно-фтористую связь нижнего слоя ПТФЭ, поверхность ПТФЭ изменяется. После травления ПТФЭ его поверхность приобретает большее трение, и его можно склеивать, формовать или приклеивать к другим материалам. Это также позволяет Трубка из ПТФЭ быть напечатанным или выгравированным.
YOZONE-Technology предлагает следующие ключевые решения для изделий из PTFE, FEP, PFA и PEEK. Итак, сегодня мы представим вам наше качество Экструдированная трубка ниже:
Поставщик трубок PTFE Экструдированные трубы - это универсальный и широко используемый в различных отраслях продукт. Она представляет собой непрерывный отрезок материала, который формируется путем продавливания через фильеру, в результате чего получается полая цилиндрическая форма.
-
PTFE подгонянный гибкий экструдированный гладкоствольный тюбинг OEM изготовитель
Product Overview
Yozonetech supplies PTFE tubing and rigid PTFE tubes for customers who need chemical resistance, thermal stability, electrical insulation and low friction. Our range covers small bore flexible tubing, standard metric and inch dimensions, and thick wall or large diameter rigid tubes. Nonstandard dimensions and special lengths can be customized to match drawings and application requirements.
PTFE stands for polytetrafluoroethylene. Its combination of chemical resistance and low surface friction makes it useful in industrial transfer lines, insulating sleeves and protective components. The right tube depends on the medium, temperature, pressure, installation space and connection method. We help customers turn those requirements into an agreed specification.
Product Highlights
Химическая стойкость
The catalog rates PTFE chemical solvent resistance as excellent. Confirm compatibility with the actual medium, concentration and operating conditions before use.
Temperature capability
The material table lists a maximum continuous operating temperature of 260°C. This is a material reference and does not establish a pressure rating at that temperature.
Low friction
A reference coefficient of friction of 0.02 against steel supports applications where low surface drag is useful.
Electrical insulation
Reference dielectric constant is 2.1 at both 10³ Hz and 10⁵ Hz, with high volume and surface resistivity.
Low water absorption
The listed 24 hour water absorption is below 0.01 percent, helping limit moisture uptake.
Choice of dimensions
Flexible sizes, inch sizes and rigid tube dimensions allow selection around flow requirements, insulation clearance and component geometry.
Technical Specifications
The following values are PTFE material reference data, not guaranteed finished tube acceptance limits. Actual performance depends on resin grade, processing, tube geometry and service conditions. Agree any required test method and acceptance limit before ordering.
Недвижимость PTFE reference value Catalog test method Relative density 2.13–2.22 ASTM D792 Прочность на разрыв 14–48 MPa ASTM D638 Удлинение при разрыве 200–450% ASTM D638 Compressive strength 24 MPa ASTM D695 Flexural modulus 490–586 MPa ASTM D790 Shore D hardness 50–60 ASTM D636 as printed Friction coefficient against steel 0.02 Not stated Melting point 320–327°C Not stated Теплопроводность 0.25 Unit not stated Maximum continuous operating temperature 260°C Catalog reference at 20000 h Flame retardance UL 94 V-0 Material reference Dielectric constant at 10³ Hz 2.1 ASTM D150 Dielectric constant at 10⁵ Hz 2.1 ASTM D150 Объемное удельное сопротивление >10¹⁸ Ω·cm ASTM D257 Surface resistivity >10¹⁷ Ω ASTM D257 Chemical solvent resistance Превосходно ASTM D543 Water absorption at 24 h <0.01% ASTM D570 Refractive index 1.35 Not stated Material reference values do not establish certification of every finished tube. The hardness method is reproduced as printed and should be confirmed if a formal test report is required. Thermal conductivity is shown without an inferred unit because the source does not provide one.
Pressure and Temperature Selection
A PTFE tube pressure rating must be specified for the selected ID, OD, wall thickness, temperature and fitting arrangement. Request the permitted working pressure for your exact tube. Do not apply the PFA or FEP pressure charts to PTFE tubing. The temperature capability of the polymer also does not authorize pressurized service at the maximum temperature.
Standard Flexible Tubing Dimensions
All dimensions below are in millimeters. ID means inner diameter; OD means outer diameter. Wall thickness is calculated as (OD − ID) ÷ 2. The catalog lists these sizes in its common fluoropolymer tubing table and refers the PTFE flexible tube range to that table. Confirm the PTFE material and dimensional tolerance when ordering.
ID mm OD mm Wall mm 0.3 0.6 0.15 1 2 0.5 1 3 1 1.5 2.5 0.5 2 3 0.5 2 4 1 2 4.5 1.25 2 5 1.5 2.5 4.5 1 3 4 0.5 3 5 1 3 6 1.5 3.5 4.5 0.5 3.5 5.5 1 4 5 0.5 4 5.5 0.75 4 6 1 4 7 1.5 4 8 2 5 6 0.5 5 7 1 5 8 1.5 5 9 2 6 7 0.5 6 7.5 0.75 6 8 1 6 9 1.5 6 10 2 6.5 8.5 1 6.5 10 1.75 7 8 0.5 7 9 1 7 10 1.5 7.5 9 0.75 7.5 10 1.25 8 10 1 8 12 2 8.5 10.5 1 9 10 0.5 9 11 1 9 12 1.5 9.5 10.5 0.5 9.5 11.5 1 10 11 0.5 10 11.5 0.75 10 12 1 10 13 1.5 11 12.5 0.75 11 13 1 12 14 1 12 15 1.5 12 16 2 13 15 1 14 16 1 15 17 1 15 18 1.5 16 19 1.5 17 19 1 17 20 1.5 18 20 1 20 22 1 20 23 1.5 22 24 1 22 25 1.5 33 38 2.5 Other sizes can be customized. A listed dimension is a catalog option rather than a statement of stock availability.
Inch Tubing Dimensions
The source expresses inch tubing as OD × ID. This table retains that order and the catalog millimeter conversions rather than silently changing rounding conventions.
OD inch ID inch OD mm ID mm 1/8 1/16 3.17 1.57 1/4 1/8 6.35 3.17 1/4 5/32 6.35 3.96 1 1/4 — 31.75 27.95 1/4 5.5/32 6.35 4.35 1/4 3/16 6.35 4.76 3/8 1/4 9.525 6.35 1 1/2 — 38.1 33.7 1/2 3/8 12.7 9.525 3/4 5/8 19.05 15.88 1 7/8 25.4 22.2 2 — 50.8 42.5 The 1/4 × 5.5/32 inch entry and its 4.35 mm ID are reproduced from the catalog. Confirm the intended nominal size before ordering. For entries with no inch ID given, use the listed millimeter bore.
Packaging and Color Options
Catalog packaging options include 10 m, 20 m, 30.4 m, 50 m, 100 m and 500 m rolls, plus 2 m straight lengths. Availability depends on the selected tube size and construction. Specify whether your production process needs continuous rolls, straight pieces or custom cut lengths.
The shared tubing table lists transparent, semitransparent, white, red, blue, black, yellow, green and multicolor options across PTFE, FEP and PFA. PTFE is typically associated with a milky white or semitransparent appearance in the catalog. Confirm the achievable color and appearance for the chosen PTFE grade; transparent options in the shared table should not be interpreted as a promise of clear PTFE.
Dimensional Ordering
Always state which diameter comes first. Metric flexible sizes here use ID × OD; rigid tube dimensions on the following pages use OD, ID and wall thickness in separate columns. For custom production, provide tolerances for both diameters, cut length, end finish and any inspection requirements.
Rigid PTFE Tube Dimensions
The following is the complete rigid tube size list from the catalog. Dimensions are in millimeters. Reference mass is the theoretical value for 1000 mm of tube, expressed in kilograms. It is not a measured shipment weight. The catalog also gives 4200 mm theoretical masses; use the confirmed finished length and actual weight for purchasing or freight planning.
OD mm ID mm Wall mm Mass kg per m 9.5 6 1.75 0.09 9.5 4 2.75 0.13 13.5 5.5 4 0.26 14.5 6.5 4 0.28 20 15 2.5 0.30 20 16 2 0.24 20 14 3 0.34 20 13 3.5 0.39 20 12 4 0.43 20 10 5 0.51 20 8 6 0.57 20.5 16.5 2 0.25 30 24 3 0.55 30 25 2.5 0.47 30 20 5 0.84 30 18 6 0.97 30.5 22.5 4 0.72 40 34 3 0.75 40 33 3.5 0.86 40 32 4 0.97 40 30 5 1.18 40 25 7.5 1.65 50 46 2 0.65 50 45 2.5 0.80 50 44 3 0.95 50 43 3.5 1.10 50 23 13.5 3.33 50 40 5 1.52 60 53 3.5 1.34 60 50 5 1.86 70 64 3 1.36 70 46 12 4.70 71 61 5 2.23 70 50 10 4.05 80 75 2.5 1.31 80 74 3 1.56 80 70 5 2.53 80 72 4 2.05 90 84 3 1.76 90 80 5 2.87 90 74 8 4.43 90 70 10 5.40 90 78 6 3.40 100 80 10 6.08 100 90 5 3.21 110 104 3 2.17 110 100 5 3.54 130 121 4.5 3.81 150 143.6 3.2 3.17 250 220 15 23.80 260 250 5 8.61 305 295 5 10.13 350 340 5 11.65 360 349 5.5 13.16 408 397 5.5 14.95 460 448 6 18.39 508 495.4 6.3 21.34 Nonstandard sizes and special lengths can be customized. The catalog size labels for some rigid tubes are shorthand; select by the explicit OD and ID columns.
Catalog Diameter Tolerance Bands
Catalog diameter band mm Listed tolerance mm 15–50 ±0.3 51–100 ±0.4 101–207 ±0.5 208–360 ±1 400–500 ±1.5 The catalog does not identify which diameter these bands control, and it leaves some sizes outside the stated bands. Confirm OD, ID and wall acceptance limits separately for every order; do not extrapolate the bands to unlisted sizes.
Система полного контроля качества технологического процесса

Определение давления воздуха
Наш сайт производители труб из птфэ использует полностью автоматическое импортное оборудование для испытания давлением воздуха с датчиком. Все трубки PTFE испытываются давлением воздуха 8 кг внутри и давление поддерживается в течение 60 секунд для предотвращения утечек газа.

Сильное световое обнаружение примесей
Источник света для обнаружения состоит из различных монохроматических источников света и составных источников света для проверки различных примесей, таких как черные примеси и парафин, которые нелегко обнаружить в процессе производства внутренних труб из ПТФЭ.

Контроллер диаметра лазера
Он может непрерывно и точно контролировать внутренний и внешний диаметры и допуски на протяжении всего процесса производства трубок из ПТФЭ

Высокотемпературный импульсный испытательный стенд
Оптовая продажа птфе трубки Компания является первым в отрасли средневысокотемпературным (+260°) импульсным стендом, который может тестировать частоту импульсов политетрафторэтиленовых трубок при различных температурах среды.

Испытание на электрический пробой (SAE J30)
Проверьте изоляцию Трубка из ПТФЭ

Тест на блеск
Искровое тестирование может более точно обнаружить небольшие утечки в трубке PTFE
Сертификаты
Технические характеристики капиллярной трубки из ПТФЭ
AWG ID OD УПАКОВКА Мин Нормальный Макс S Model Модель T L Модель 30 0.25 0.30 0.38 0.76 0.76 0.60 305 28 0.33 0.38 0.46 0.84 0.84 0.68 305 26 0.41 0.46 0.53 0.92 0.92 0.76 305 24 0.51 0.56 0.66 1.16 1.06 0.86 305 23 0.58 0.66 0.74 1.26 1.16 0.96 305 22 0.66 0.71 0.81 1.31 1.21 1.01 305 21 0.74 0.81 0.89 1.41 1.31 1.11 305 20 0.81 0.86 0.97 1.66 1.46 1.16 305 19 0.91 0.96 1.07 1.76 1.56 1.26 305 18 1.01 1.07 1.17 1.87 1.67 1.37 305 17 1.14 1.19 1.32 1.99 1.79 1.49 305 16 1.29 1.34 1.47 2.14 1.94 1.64 305 15 1.45 1.50 1.65 2.30 2.10 1.80 153 14 1.62 1.68 1.83 2.48 2.28 2.08 153 13 1.83 1.93 2.05 2.73 2.53 2.33 153 12 2.05 2.16 2.31 2.96 2.77 2.56 153 11 2.31 2.41 2.57 3.21 3.01 2.81 153 10 2.59 2.69 2.84 3.49 3.29 3.09 100 9 2.90 3.00 3.15 4.00 3.76 3.40 100 8 3.28 3.38 3.53 4.38 4.14 3.78 100 7 3.65 3.76 3.94 4.76 4.52 4.16 100 6 4.11 4.22 4.41 5.22 4.98 4.72 100 5 4.62 4.72 4.95 5.72 5.48 5.22 100 4 5.18 5.28 5.53 6.28 6.04 5.78 100 3 5.81 5.94 6.20 6.94 6.70 6.44 100 2 6.55 6.68 6.93 7.68 7.44 7.18 100 1 7.34 7.46 7.75 8.48 6.22 7.96 100 0 8.26 8.38 8.69 9.38 9.14 8.88 100 Applications and Selection
Industrial Chemical Transfer
PTFE tubing is a candidate for industrial lines exposed to chemically demanding media. Select the tube around the actual fluid and concentration, including any cleaning chemicals. Chemical resistance alone does not determine whether a tube is suitable: pressure, permeation, temperature and connection integrity also matter. Send the full operating conditions for technical review.
Electrical and Electronic Insulation
Small bore PTFE tubing can serve as an insulating sleeve around wires or components when its dimensions and electrical performance match the design. Low water absorption and the catalog electrical reference data support this selection process. Required voltage performance must be verified for the finished wall thickness and assembly.
Laboratory and Analytical Equipment
PTFE tubing may be considered for reagent transfer and protective sleeves in laboratory equipment. Specify bore size, routing, dead volume constraints and connection dimensions. Applications sensitive to contamination should define cleanliness, extractables and packaging requirements separately rather than assuming that every standard industrial tube meets them.
Machinery and Protective Components
Rigid PTFE tubes provide hollow stock for sleeves, spacers or other components where a tubular starting shape is useful. Select enough wall thickness for the final geometry and machining allowance. Review mechanical loading, dimensional stability and friction behavior under the actual operating conditions.
Semiconductor and Medical Equipment Selection
For semiconductor applications, define purity, particle and contamination requirements before selecting a grade. Standard PTFE tubing is not automatically qualified for high purity chemical delivery. For medical equipment, consider only appropriately reviewed external or nonpatient contact functions: this catalog specifically prohibits direct contact with biological tissues or fluids and use inside the human body. Medical contact applications require a separately qualified product and supporting evidence.
Choosing the Tube Construction
Flexible tubing is suited to installations that need routing flexibility and a small outside diameter. Rigid tubing is intended for layouts or components that benefit from a stiffer tubular form. Neither construction should be selected solely by name. Check the actual size, allowable pressure, installation geometry and joint design.
Capillary tubing, spiral cut tubing, corrugated tubing, heat shrink tubing and braided hose are separate product constructions. Their own size tables and performance data should be used when those functions are required; a smooth tube specification does not qualify them interchangeably.
Custom Production and Quality Requirements
Yozonetech manufactures standard and customized polymer products according to drawings and agreed specifications. Our company capabilities include extrusion, injection molding, blow molding and CNC machining or turning across the wider product range. Our quality management systems include ISO 9001 and ISO 45001.
Custom Specifications
For a custom PTFE tube, provide ID, OD, wall thickness, length and dimensional tolerance. Add resin grade requirements, color, surface condition, end finish and preferred packaging. For a machined rigid component, include a drawing with critical features, datum references and the inspection method needed for those features.
Inspection and Documentation
Agree the inspection plan before production. Relevant items may include diameter and wall measurements, ovality, length, visible defects, end condition and identification. If pressure performance is required, specify the test conditions and acceptance criteria for the finished tube and its intended fittings. Material documentation, certificates and any application specific reports should be confirmed at quotation stage.
A polymer property table is useful for initial selection, but it does not replace a batch test report or finished product qualification. Any requirement for food contact, biocompatibility, flame testing, restricted substances or special cleanliness must be tied to the actual grade and supplied product.
Installation and Use
Use the product only for its agreed application and within the confirmed service temperature and pressure limits. Allow a routing radius that avoids flattening or kinking, and confirm bend performance for the exact tube. Do not use another material’s bend radius table as a PTFE specification.
Support the tube to prevent strain at connections. Use fittings compatible with the chosen tube material and dimensions, and confirm the assembled system rating. Review the line after repeated use for abrasion, damage, hardening, dimensional change or signs of leakage. The catalog recommends periodic replacement where recurring friction may cause deterioration.
For acids, alkalis and highly hazardous media, consult technical personnel and confirm suitability before use. Keep tubing away from fire and welding. Processing above the stated maximum service temperature may release fluoropolymer decomposition gases; maintain adequate ventilation and follow the product safety data sheet. Dispose of used material in accordance with applicable local requirements.
Request a PTFE Tube Quotation
Send your required quantity, ID and OD or drawing, length, tolerances, color and packaging. Include the medium, concentration, normal and maximum temperature, working pressure and fitting type. For equipment qualification, add the standards and reports required. We can then review the specification and confirm supply details.
Website: www.chinaptfetube.com
Электронная почта: ptfetube@yozonetech.cn
WhatsApp / Tel / WeChat: +86 13752771911Frequently Asked Questions
1 What is PTFE tubing used for
PTFE tubing is used where chemical resistance, insulation or low friction is needed. Candidate applications include industrial fluid lines, insulating sleeves, laboratory equipment and protective components. Confirm the tube against the actual service conditions.
2 What is the difference between flexible and rigid PTFE tubes
Flexible tubing allows easier routing, while rigid tubes provide a stiffer tubular form and can serve as stock for components. Size, wall thickness and construction determine practical behavior, so compare the exact product specifications.
3 Which standard metric sizes are available
The common flexible tubing table lists ID values from 0.3 to 33 mm and OD values from 0.6 to 38 mm. The rigid tube table spans OD 9.5 to 508 mm. These are listed catalog options, with nonstandard dimensions available for review.
4 Can you supply inch sizes
Yes. Catalog options include 1/8, 1/4, 3/8, 1/2, 3/4 and 1 inch outside diameters, plus larger entries. Specify both OD and ID because a nominal inch diameter alone does not define the bore or wall thickness.
5 What is the maximum operating temperature
The material reference table lists 260°C as the maximum continuous operating temperature. Confirm the finished tube service limits for its load, pressure and installation. The melting point of 320–327°C is not an operating temperature.
6 What working pressure can PTFE tubing withstand
There is no single rating covering this entire range. Working pressure must be confirmed for the actual tube dimensions, material, service temperature and fittings. Provide those details when requesting a quotation.
7 Are the listed material properties guaranteed for every tube
No. The catalog states that technical performance data are experimental reference values rather than guaranteed limits. Required properties and acceptance criteria must be agreed for the supplied product.
8 Is this PTFE tubing suitable for direct medical contact
The catalog prohibits contact with biological tissues or fluids and use inside the human body. Do not use this standard industrial range for direct patient contact. Such applications need a separately qualified product and documentation.
9 Can dimensions and colors be customized
Nonstandard sizes and special lengths can be reviewed. Color availability should be confirmed for PTFE rather than inferred from the shared PTFE, FEP and PFA color list. State the desired appearance and tolerances in your inquiry.
10 How is the tubing packaged
Catalog options include rolls of 10, 20, 30.4, 50, 100 and 500 meters and 2 meter straight lengths. Confirm the packaging option for your selected size, or request custom cut lengths and protective packaging requirements.
-
PTFE SS304/316 оплетка шланга SAE100R14 для промышленности и пищевого класса
Product Overview
Smooth bore and convoluted PTFE hose with stainless steel and polymer fiber reinforcement
Yozonetech supplies PTFE braided hose for industrial fluid transfer, chemical handling and hydraulic connections. Choose a smooth-bore liner for a clear flow path or a convoluted liner for more flexible routing. Liner options include conventional PTFE, imported PTFE resin and carbon-black-filled conductive PTFE. Reinforcement options include 304 and 316L stainless steel wire, polyester yarn and Kevlar aramid fiber.
We can produce two- and three-layer braided constructions, including combinations of stainless steel and polymer fiber layers. Each configuration is matched to the required pressure, temperature, routing and end connections. Send your application details or drawing to request a quotation.
Testing and Inspection
A hose inspection plan can cover liner integrity, dimensional control, pressure performance and material properties. Specify the tests and acceptance criteria required for your order. Equipment capacity, test method and reporting requirements are confirmed with the selected supply configuration.
Automatic pneumatic leak testing
PTFE inner tubes can be checked for leakage using automatic air-pressure testing with a 60-second pressure hold. The test pressure must be stated in a defined unit and agreed for the liner being supplied.
Strong light inspection
Monochromatic and combined light sources help reveal black particles, paraffin and other visible contamination in the PTFE liner.
Laser dimensional control
Laser diameter measurement supports dimensional monitoring during liner production. Inner diameter, outer diameter and wall acceptance limits are defined in the inspection plan.
Spark testing
Electrical spark testing screens the PTFE liner for pinholes and small defects. Agree test voltage and method for the liner wall and construction.
Hydrostatic and burst pressure testing
Hydrostatic equipment evaluates braided hose pressure integrity, with proof-test criteria specified for the selected hose. Burst testing evaluates ultimate pressure performance; the reference burst-test bench has a maximum capacity of 200 MPa, which is an equipment limit rather than a hose rating.
Temperature impulse and flex testing
High-temperature impulse testing evaluates pressure cycling at media temperatures up to +260°C in the reference setup. A temperature-controlled bending test bench provides environmental conditions from -60°C to +300°C. These equipment ranges do not define the operating limits of the finished hose.
Tensile and electrical tests
Tensile testing measures PTFE liner strength and elongation, with D638 identified as a reference method. Electrical breakdown testing evaluates liner insulation. Test standards, specimen preparation and acceptance limits are agreed for the applicable product.
Liner and Reinforcement Options
Smooth bore PTFE liner
A milky-white PTFE liner with a smooth internal surface provides a clear flow path for fluid transfer. The R-series reference construction uses one reinforcing layer of 304 stainless steel wire. The smooth-bore reference is not recommended for dynamic applications; specify motion and pressure cycling separately when selecting the finished assembly.
Convoluted PTFE liner
A milky-white PTFE liner with an internally corrugated profile provides greater routing flexibility and a smaller bend radius. The R-series reference uses one reinforcing layer of 304 stainless steel wire and identifies this construction for dynamic use. Repeated flexing still requires confirmation of bend radius, displacement, cycle rate and service life.
304 and 316L stainless steel braid
Choose 304 or 316L stainless steel wire reinforcement according to the installation environment and required construction. Specify external exposure, corrosion concerns and fitting materials together with the fluid-side requirements.
Polyester and Kevlar braid
Polyester yarn and Kevlar aramid fiber are available as polymer reinforcement options. Select the fiber against the required temperature, mechanical duty and external exposure; the PTFE liner temperature range does not automatically apply to every polymer braid.
Two and three layer mixed braiding
We can braid two or three layers using stainless steel wire, polymer fiber yarn or a combination of both. Specify the reinforcement materials and layer arrangement for review. Pressure ratings, bend behavior, outside diameter and end-fitting retention must be established for each finished construction; adding layers does not create a universal pressure rating.
Imported PTFE resin options
Imported PTFE resin options include Japanese Daikin 302 dispersion resin as identified for the imported-material constructions. Smooth-bore, convoluted, thick-wall and smooth-inside corrugated-outside forms can be specified. Confirm the resin manufacturer, exact grade and traceability requirements in the order specification.
Carbon black conductive PTFE liners
Carbon-black-filled PTFE is available for applications requiring a conductive fluid-contact liner. Options include a black liner and a composite liner with a blue exterior and black conductive inner layer. Specify the required electrical resistance, test method and grounding arrangement for the complete assembly. A conductive liner does not by itself establish a hazardous-area approval.
Smooth inside corrugated outside liners
This construction combines a smooth fluid-contact bore with an externally corrugated profile, with unbraided and stainless-steel-reinforced reference versions. The smooth bore avoids internal corrugation pockets; drainage and residue behavior still depend on routing, fluid and cleaning conditions.
Product Benefits
- PTFE fluid-contact liner for a broad range of hydraulic fluids and chemicals, subject to compatibility review for the actual medium and concentration.
- Smooth-bore and convoluted options to match flow-path and routing requirements.
- Stainless steel and polymer fiber reinforcement choices for application-specific assemblies.
- Two- and three-layer construction, including metal and fiber combinations.
- Inspection and test requirements tailored to the agreed hose specification.
Technical Parameters
Диапазон температур
The reference PTFE hose families share a listed temperature range of -50°C to +260°C. The permitted range of a supplied assembly depends on liner grade, braid materials, layer arrangement, fittings, seals, pressure and service conditions. Polymer-braided and mixed constructions require their own confirmed limits.
Pressure reduction for conventional conductive and high pressure constructions
For R, G, B, O and Z reference families, the pressure factors are 0.75 at 170°C, 0.65 at 180°C and 0.40 at 205°C. Permitted working pressure = the selected hose base working pressure × the applicable temperature factor. These values apply only to the corresponding confirmed construction.
Pressure reduction for imported W and Y constructions
The imported-resin W and Y reference families use factors of 0.85 at 170°C, 0.75 at 180°C and 0.50 at 205°C. These factors must not be transferred to other imported-resin products: the imported ultra-high-pressure O version and Z family retain the 0.75, 0.65 and 0.40 factors. Confirm factors at all other temperatures rather than extrapolating to +260°C.
Static and dynamic selection
Smooth-bore R, G, B, W and Y references, the two O high-pressure constructions and unbraided Z are not recommended for dynamic high-load service. Convoluted R and G and reinforced Z are identified for dynamic use; confirm motion, bend radius, pressure cycling and required life for the selected assembly. The B conductive family is not recommended for water or steam circuits. Its convoluted version requires separate review for dynamic duty.
Performance and material documentation
SAE 100 R14 is the stated performance reference for G, while R, W, Y and Z are described as exceeding that reference. These catalog descriptions are not a certification of every Yozonetech configuration. Confirm the applicable standard edition, test scope and supporting results for the supplied product. PTFE material documentation against 21 CFR 177.1550 may be requested where relevant; evaluate the exact compound and complete assembly separately, including conductive fillers.
Ratings for custom reinforcement
All numerical ranges below belong to the identified reference constructions. They do not establish ratings for 316L, polyester, Kevlar or two- and three-layer mixed braids. Confirm the product-specific pressure, burst requirement, temperature limits, bend radius, conductivity and weight in the quotation. A range maximum is not available at every diameter.
Pressure Enhanced PTFE R
Milky-white PTFE with one reinforcing layer of 304 stainless steel braid. Smooth-bore construction is intended for static installations; the convoluted reference is identified for dynamic use, subject to confirmation of movement and fatigue requirements.
Work = maximum working pressure; Burst = minimum burst pressure; Bend = minimum bend radius; Mass = reference weight. Values are specific to the listed construction and size.
Smooth Bore R Sizes
Модель ID
ммID
inchOD
ммOD
inchWork
barWork
psiBurst
barBurst
psiBend
ммMass
kg/m1R-3 3.2 1/8 6.2 0.24 245 3552 1050 15225 12 0.075 1R-4 5 3/16 8 0.31 192 2791 870 12615 15 0.095 1R-5 6.3 1/4 9.2 0.36 180 2610 840 12180 16 0.115 1R-6 8 5/16 11.2 0.44 192 2791 770 11165 20 0.142 1R-7 9.7 3/8 13 0.51 172 2500 690 10000 35 0.173 1R-8 10.3 13/32 13.5 0.53 170 2465 680 9860 35 0.2 1R-10 12.7 1/2 16.5 0.65 160 2320 640 9280 55 0.242 1R-12 16.2 5/8 19.5 0.77 137 1993 550 7975 80 0.29 1R-14 19 3/4 23.5 0.93 95 1377 380 5510 125 0.43 1R-16 22.2 7/8 26.5 1.04 87 1268 350 5075 175 0.48 1R-18 25 1 29.8 1.17 75 1087 300 4350 200 0.54 Convoluted R Sizes
Модель ID
ммID
inchOD
ммOD
inchWork
barWork
psiBurst
barBurst
psiBend
ммMass
kg/m2R-5 6.3 1/4 10.5 0.41 162 2356 650 9425 9 0.142 2R-6 8 5/16 12.2 0.48 142 2066 570 8565 11 0.178 2R-7 9.7 3/8 15.5 0.61 135 1957 540 7830 20 0.273 2R-10 12.7 1/2 18.5 0.73 117 1703 470 6815 40 0.3 2R-12 16.2 5/8 22.5 0.89 80 1160 320 4640 50 0.42 2R-14 19 3/4 25.5 1 72 1051 290 4205 65 0.48 2R-16 22.2 7/8 28.5 1.12 63 924 255 3697.5 75 0.58 2R-18 25 1 35.5 1.40 58 851 235 3407.5 90 0.74 2R-20 32 1 1/4 42.5 1.67 52 761 210 3045 100 1 2R-24 38 1 1/2 51.5 2.03 50 725 200 2900 105 1.28 2R-32 51 2 60.5 2.38 45 652 180 2610 130 1.38 Reference temperature factors: 0.75 at 170°C, 0.65 at 180°C and 0.40 at 205°C. Confirm the selected assembly rating and operating conditions.
Standard PTFE G
Milky-white PTFE with one 304 stainless steel braid. The G reference identifies SAE 100 R14 as the performance standard. Smooth-bore construction is not recommended for dynamic use; the convoluted version requires application-specific motion review.
Work = maximum working pressure; Burst = minimum burst pressure; Bend = minimum bend radius; Mass = reference weight. Values are specific to the listed construction and size.
Smooth Bore G Sizes
Модель ID
ммID
inchOD
ммOD
inchWork
barWork
psiBurst
barBurst
psiBend
ммMass
kg/m1G-3 3.2 1/8 6.2 0.24 200 3190 850 12325 12 0.07 1G-4 5 3/16 7.8 0.3 140 2030 600 8700 15 0.09 1G-5 6.3 1/4 9.1 0.35 137 1986 600 8700 16 0.11 1G-6 8 5/16 10.8 0.43 125 1812 480 6960 20 0.135 1G-7 9.7 3/8 12.6 0.49 110 1595 420 6525 35 0.165 1G-10 12.7 1/2 16.2 0.64 95 1410 400 5960 55 0.230 1G-12 16.2 5/8 19.3 0.76 85 1260 360 5364 80 0.276 1G-14 19 3/4 22.5 0.88 52 754 210 3045 125 0.405 Convoluted G Sizes
Модель ID
ммID
inchOD
ммOD
inchWork
barWork
psiBurst
barBurst
psiBend
ммMass
kg/m2G-5 6.4 1/4 10.5 0.41 117 1703 470 6815 9 0.135 2G-6 8 5/16 12.2 0.48 97 1413 390 5665 11 0.17 2G-7 10 3/8 15.5 0.61 87 1268 350 5075 20 0.26 2G-10 13 1/2 18.5 0.73 77 1123 310 4495 40 0.29 2G-12 16.2 5/8 22.5 0.89 57 833 230 3335 50 0.4 2G-14 19 3/4 25.5 1 57 833 230 3335 65 0.5 2G-16 22.2 7/8 28.5 1.12 50 725 200 2900 75 0.55 2G-18 25.4 1 35.5 1.40 60 870 240 3480 90 0.7 Reference temperature factors: 0.75 at 170°C, 0.65 at 180°C and 0.40 at 205°C. Confirm the selected assembly rating and operating conditions. The bar and psi columns reproduce the catalog values; some pairs differ from direct unit conversion. Confirm one agreed pressure rating and unit before use.
High Pressure PTFE O
The first construction combines a smooth-bore milky-white liner, two reinforced 304 stainless steel braids and a special intermediate adhesive layer. The imported ultra-high-pressure version uses Daikin 302 dispersion resin, a thickened smooth bore and multi-strand braiding, with a light-blue semitransparent liner. Both references exclude dynamic high-load service.
Work = maximum working pressure; Burst = minimum burst pressure; Bend = minimum bend radius; Mass = reference weight. Values are specific to the listed construction and size.
Double Braid High Pressure O Sizes
Модель ID
ммID
inchOD
ммOD
inchWork
barWork
psiBurst
barBurst
psiBend
ммMass
kg/m1O-5 6.3 1/4 10.4 0.4 275 3987 1100 15950 15 0.137 1O-6 8 5/16 12.2 0.48 237 3443 950 13775 19 0.23 1O-7 9.7 3/8 14.3 0.56 225 3262 900 13050 35 0.284 1O-10 12.7 1/2 18 0.7 200 2900 800 11600 50 0.442 1O-12 16.2 5/8 21 0.82 177 2573 710 10295 80 0.56 1O-14 19 3/4 25 0.98 155 2247 620 8990 125 0.61 1O-18 25 1 31.2 1.22 125 1812 500 7250 175 0.92 Imported Ultra High Pressure O Sizes
Модель ID
ммID
inchOD
ммOD
inchWork
barWork
psiBurst
barBurst
psiBend
ммMass
kg/m2O-6 8 5/16 14 0.55 362 5393 1450 21605 60 0.45 2O-7 9.7 3/8 16 0.63 325 4842 1300 19370 80 0.5 2O-10 12.7 1/2 19.5 0.77 287 4276 1150 17135 125 0.65 2O-12 16.2 5/8 22 0.87 250 3725 1000 14900 160 0.78 2O-14 19 3/4 25.5 1 232 3457 930 13857 180 1 2O-18 25 1 31.5 1.24 200 2980 800 11920 200 1.38 Reference temperature factors: 0.75 at 170°C, 0.65 at 180°C and 0.40 at 205°C. Confirm the selected assembly rating and operating conditions. Multi-strand braid structure is distinct from the number of braid layers.
Conductive PTFE B
Black PTFE liner with static-conductive properties and one 304 stainless steel braid. Carbon-black-filled material is an option for conductive fluid-contact liners. Specify electrical resistance and assembly grounding requirements. The B reference is not recommended for water or steam circuits; dynamic duty requires separate review.
Work = maximum working pressure; Burst = minimum burst pressure; Bend = minimum bend radius; Mass = reference weight. Values are specific to the listed construction and size.
Smooth Bore Conductive B Sizes
Модель ID
ммID
inchOD
ммOD
inchWork
barWork
psiBurst
barBurst
psiBend
ммMass
kg/m1B-3 3.2 1/8 6.2 0.24 250 3625 1000 14500 12 0.07 1B-4 5 3/16 7.8 0.3 155 2247 620 8990 15 0.09 1B-5 6.3 1/4 9.1 0.35 137 1993 550 7975 16 0.11 1B-6 8 5/16 10.8 0.43 135 1957 540 7830 20 0.135 1B-7 9.7 3/8 12.6 0.49 132 1321 530 7685 35 0.165 1B-8 10.3 13/32 13.2 0.52 127 1848 510 7395 35 0.18 1B-10 12.7 1/2 16.2 0.64 105 1522 390 6090 55 0.230 1B-12 16.2 5/8 19.3 0.76 95 1377 350 5510 80 0.276 1B-14 19 3/4 22.5 0.88 52 761 210 3045 125 0.405 1B-16 22.2 7/8 26 1.02 50 725 200 2900 175 0.460 1B-18 25 1 29.5 1.16 50 725 200 2900 200 0.51 Convoluted Conductive B Sizes
Модель ID
ммID
inchOD
ммOD
inchWork
barWork
psiBurst
barBurst
psiBend
ммMass
kg/m2B-5 6.4 1/4 10.5 0.41 117 1703 470 6815 9 0.135 2B-6 8 5/16 12.2 0.48 97 1413 390 5665 11 0.17 2B-7 10 3/8 15.5 0.61 87 1268 350 5075 20 0.26 2B-10 13 1/2 18.5 0.73 77 1123 310 4495 40 0.29 2B-12 16.2 5/8 22.5 0.89 57 833 230 3335 50 0.4 2B-14 19 3/4 25.5 1 57 833 230 3335 65 0.5 2B-16 22.2 7/8 28.5 1.12 50 725 200 2900 75 0.55 2B-18 25.4 1 35.5 1.40 60 870 240 3480 90 0.7 2B-20 32 1 1/4 42.5 1.67 52 761 210 3045 100 0.95 2B-24 38 1 1/2 51.5 2.03 50 725 200 2900 105 1.22 2B-32 51 2 60.5 2.38 45 652 180 2610 130 1.38 Reference temperature factors: 0.75 at 170°C, 0.65 at 180°C and 0.40 at 205°C. Confirm the selected assembly rating and operating conditions. Catalog pressure pairs are retained as listed, including inconsistent bar and psi values. Confirm the ordered product rating before use.
Imported Conductive Composite PTFE W
Daikin 302 imported-resin reference with a blue exterior and black conductive inner layer, reinforced by one 304 stainless steel braid. Smooth-bore and convoluted versions are listed. Confirm resin traceability, electrical resistance, connection continuity and the movement requirements of the finished assembly.
Work = maximum working pressure; Burst = minimum burst pressure; Bend = minimum bend radius; Mass = reference weight. Values are specific to the listed construction and size.
Smooth Bore Conductive W Sizes
Модель ID
ммID
inchOD
ммOD
inchWork
barWork
psiBurst
barBurst
psiBend
ммMass
kg/m1W-3 3.2 1/8 6.2 0.24 245 3552 1050 15225 12 0.075 1W-4 5 3/16 8 0.31 192 2791 870 12615 15 0.095 1W-5 6.3 1/4 9.2 0.36 180 2610 840 12180 16 0.115 1W-6 8 5/16 11.2 0.44 192 2791 770 11165 20 0.142 1W-7 9.7 3/8 13 0.51 172 2500 690 10000 35 0.173 1W-8 10.3 13/32 13.5 0.53 170 2465 680 9860 35 0.2 1W-10 12.7 1/2 16.5 0.65 160 2320 640 9280 55 0.242 1W-12 16.2 5/8 19.5 0.77 137 1993 550 7975 80 0.29 1W-14 19 3/4 23.5 0.93 95 1377 380 5510 125 0.43 1W-16 22.2 7/8 26.5 1.04 87 1268 350 5075 175 0.48 1W-18 25 1 29.8 1.17 75 1087 300 4350 200 0.54 Convoluted Conductive W Sizes
Модель ID
ммID
inchOD
ммOD
inchWork
barWork
psiBurst
barBurst
psiBend
ммMass
kg/m2W-5 6.3 1/4 10.5 0.41 162 2356 650 9425 9 0.142 2W-6 8 5/16 12.2 0.48 142 2066 570 8565 11 0.178 2W-7 9.7 3/8 15.5 0.61 135 1957 540 7830 20 0.273 2W-10 12.7 1/2 18.5 0.73 117 1703 470 6815 40 0.3 2W-12 16.2 5/8 22.5 0.89 80 1160 320 4640 50 0.42 2W-14 19 3/4 25.5 1 72 1051 290 4205 65 0.48 2W-16 22.2 7/8 28.5 1.12 63 924 255 3697.5 75 0.58 2W-18 25 1 35.5 1.40 58 851 235 3407.5 90 0.74 2W-20 32 1 1/4 42.5 1.67 52 761 210 3045 100 1 2W-24 38 1 1/2 51.5 2.03 50 725 200 2900 105 1.28 2W-32 51 2 60.5 2.38 45 652 180 2610 130 1.38 Reference temperature factors: 0.85 at 170°C, 0.75 at 180°C and 0.50 at 205°C. Confirm the selected assembly rating and operating conditions.
Imported Semitransparent PTFE Y
Daikin 302 imported-resin reference with a light-blue semitransparent liner and one reinforced 304 stainless steel braid. The smooth-bore and convoluted versions share the technical ranges shown below, with construction-specific dimensions and bend radii. This liner is distinct from the conductive inner-layer option.
Work = maximum working pressure; Burst = minimum burst pressure; Bend = minimum bend radius; Mass = reference weight. Values are specific to the listed construction and size.
Smooth Bore Imported Y Sizes
Модель ID
ммID
inchOD
ммOD
inchWork
barWork
psiBurst
barBurst
psiBend
ммMass
kg/m1Y-3 3.2 1/8 6.2 0.24 245 3552 1050 15225 12 0.075 1Y-4 5 3/16 8 0.31 192 2791 870 12615 15 0.095 1Y-5 6.3 1/4 9.2 0.36 180 2610 840 12180 16 0.115 1Y-6 8 5/16 11.2 0.44 192 2791 770 11165 20 0.142 1Y-7 9.7 3/8 13 0.51 172 2500 690 10000 35 0.173 1Y-8 10.3 13/32 13.5 0.53 170 2465 680 9860 35 0.2 1Y-10 12.7 1/2 16.5 0.65 160 2320 640 9280 55 0.242 1Y-12 16.2 5/8 19.5 0.77 137 1993 550 7975 80 0.29 1Y-14 19 3/4 23.5 0.93 95 1377 380 5510 125 0.43 1Y-16 22.2 7/8 26.5 1.04 87 1268 350 5075 175 0.48 1Y-18 25 1 29.8 1.17 75 1087 300 4350 200 0.54 Convoluted Imported Y Sizes
Модель ID
ммID
inchOD
ммOD
inchWork
barWork
psiBurst
barBurst
psiBend
ммMass
kg/m2Y-5 6.3 1/4 10.5 0.41 162 2356 650 9425 9 0.142 2Y-6 8 5/16 12.2 0.48 142 2066 570 8565 11 0.178 2Y-7 9.7 3/8 15.5 0.61 135 1957 540 7830 20 0.273 2Y-10 12.7 1/2 18.5 0.73 117 1703 470 6815 40 0.3 2Y-12 16.2 5/8 22.5 0.89 80 1160 320 4640 50 0.42 2Y-14 19 3/4 25.5 1 72 1051 290 4205 65 0.48 2Y-16 22.2 7/8 28.5 1.12 63 924 255 3697.5 75 0.58 2Y-18 25 1 35.5 1.40 58 851 235 3407.5 90 0.74 2Y-20 32 1 1/4 42.5 1.67 52 761 210 3045 100 1 2Y-24 38 1 1/2 51.5 2.03 50 725 200 2900 105 1.28 2Y-32 51 2 60.5 2.38 45 652 180 2610 130 1.38 Reference temperature factors: 0.85 at 170°C, 0.75 at 180°C and 0.50 at 205°C. Confirm the selected assembly rating and operating conditions.
Imported Smooth Inside Corrugated Outside PTFE Z
Daikin 302 transparent PTFE with a smooth fluid-contact bore and externally corrugated profile. The unbraided reference is not recommended for dynamic use. The version with one reinforced 304 stainless steel braid is identified for dynamic use, subject to confirmation of duty and assembly design.
Work = maximum working pressure; Burst = minimum burst pressure; Bend = minimum bend radius; Mass = reference weight. Values are specific to the listed construction and size.
Unbraided Smooth Inside Corrugated Outside Z Sizes
Модель ID
ммID
inchOD
ммOD
inchWork
barWork
psiBurst
barBurst
psiBend
ммMass
kg/m1R-5 6.3 1/4 9.3 0.36 180 2610 500 7450 20 0.115 1R-6 8 5/16 11.0 0.44 192 2791 450 6705 23 0.142 1R-7 9.7 3/8 12.7 0.51 172 2500 420 6258 40 0.173 1R-8 10.3 13/32 13.3 0.53 170 2465 390 5811 40 0.2 1R-10 12.7 1/2 15.7 0.65 160 2320 350 5215 60 0.242 1R-12 16.2 5/8 19.2 0.77 137 1993 320 4768 88 0.29 1R-14 19 3/4 22 0.93 95 1377 280 4172 130 0.43 1R-16 22.2 7/8 25.2 1.04 87 1268 260 3874 190 0.48 1R-18 25 1 28.0 1.17 75 1087 220 3278 220 0.54 Reinforced Smooth Inside Corrugated Outside Z Sizes
Модель ID
ммID
inchOD
ммOD
inchWork
barWork
psiBurst
barBurst
psiBend
ммMass
kg/m2R-5 6.3 1/4 10.6 0.41 162 2356 650 9425 25 0.142 2R-6 8 5/16 12.2 0.48 142 2066 570 8565 35 0.178 2R-7 9.7 3/8 14.2 0.61 135 1957 540 7830 40 0.273 2R-10 12.7 1/2 17.2 0.73 117 1703 470 6815 80 0.3 2R-12 16.2 5/8 20.5 0.89 80 1160 320 4640 90 0.42 2R-14 19 3/4 23.5 1 72 1051 290 4205 100 0.48 2R-16 22.2 7/8 26.5 1.12 63 924 255 3697.5 110 0.58 2R-18 25 1 29.5 1.40 58 851 235 3407.5 130 0.74 2R-20 32 1 1/4 37.5 1.67 52 761 210 3045 160 1 2R-24 38 1 1/2 43.5 2.03 50 725 200 2900 180 1.28 2R-32 51 2 56.5 2.38 45 652 180 2610 210 1.38 Reference temperature factors: 0.75 at 170°C, 0.65 at 180°C and 0.40 at 205°C. Confirm the selected assembly rating and operating conditions. Model labels beginning 1R and 2R are retained from the Z tables. Identify the Z construction explicitly when ordering to avoid confusion with R products.
Conductive Liner Selection
For fluids or processes that require static-charge dissipation, specify a carbon-black conductive liner or the conductive inner-layer construction. Define the medium, required electrical resistance, continuity through the fittings and the grounding arrangement. Verify these properties on the finished assembly; external metal braid alone does not establish conductivity through the fluid-contact PTFE liner.
Conductive and insulating requirements are different. Electrical breakdown testing is relevant to insulation assessment; a conductive assembly requires its own resistance or continuity checks. Agree the applicable test rather than assigning an insulation requirement to a conductive liner.
Installation Requirements
Select the hose and fittings as a complete assembly. Maintain the confirmed minimum bend radius, provide suitable support and avoid torsion, sharp bends at the fittings and contact with abrasive edges. For moving equipment, define the motion path and cycle duty before choosing the liner and reinforcement.
Burst pressure is a destructive test criterion and must not be used as an operating pressure. Temperature factors and reference dimensions must be confirmed for the exact hose rather than transferred between constructions.
Типовые применения
Chemical fluid transfer
Transfer connections for chemically demanding liquids where PTFE compatibility and the complete hose specification meet the process requirements. Include medium, concentration, temperature, pressure and cleaning conditions in the inquiry.
Hydraulic and industrial equipment
Connections for compatible hydraulic fluids and industrial process media. Match the hose, reinforcement and fittings to pressure cycling, routing and external exposure.
High temperature process connections
Fluid connections that require PTFE thermal performance. Review pressure reduction and the temperature capability of every braid layer, fitting and seal.
Flexible equipment connections
Convoluted constructions can be reviewed for installations requiring tighter routing or movement. Confirm displacement, frequency, minimum bend radius and fatigue requirements.
Frequently Asked Questions
Can stainless steel and polymer fibers be combined
Yes. We can supply two- and three-layer braiding that combines stainless steel wire with polymer fiber yarn. Provide the required material arrangement and application conditions for review.
Can I request imported or conductive PTFE
Yes. Specify the resin manufacturer and grade, or request a carbon-black-filled liner or conductive inner-layer construction. Include traceability and electrical resistance requirements in the inquiry.
Which stainless steel grades are available
304 and 316L stainless steel braid are available. Specify the external environment and connection requirements so the reinforcement and fitting materials can be selected together.
Do additional braid layers always increase working pressure
The effect depends on the braid design, liner, manufacturing process and fitting retention. A two- or three-layer construction needs its own confirmed rating and test criteria.
Can all constructions operate at 260 degrees Celsius
No. The -50°C to +260°C range is the R-series PTFE hose reference. Polymer braid, fittings, seals and elevated-temperature pressure reduction may impose a lower finished-assembly limit.
Should I choose smooth bore or convoluted
Choose smooth bore when a smooth internal flow path suits the application. Consider convoluted PTFE when routing flexibility or movement is required. Confirm pressure, flow, bend radius and dynamic duty for the selected assembly.
Request a PTFE Braided Hose Quote
Send the liner type, conventional or imported resin grade, conductive or insulating requirement, ID, finished length, reinforcement material and two- or three-layer arrangement, required quantity and fitting details. Include the medium, concentration, normal and maximum temperature, pressure or vacuum, bend radius, movement and cycle requirements. Add any inspection, cleanliness and documentation requirements.
Электронная почта: ptfetube@yozonetech.cn
WhatsApp / Tel / WeChat: +86 13752771911
Website: www.chinaptfetube.com
+86-13752771911
E-mail:ptfetube@yozonetech.cn