Product Overview
Yozonetech clear PVC unreinforced tubing provides a visible, flexible flow path for compatible liquids, drainage and low-pressure equipment connections. The smooth bore supports fluid transfer, while the transparent wall helps operators inspect flow, bubbles and deposits. Round tubing is complemented by custom clear PVC rectangular tubing for compact OEM layouts, protective sleeves and purpose-designed channels.

Product advantages
Clear PVC combines practical handling with visibility of the contents. Unreinforced construction is easy to cut and route, and avoids the visual obstruction of a braid or wire helix. Multiple bore and wall combinations help match fittings and installation space. For flat or confined layouts, a rectangular profile can provide a closer geometric fit than a round tube.

Приложения
Water transfer and drainage
Connect reservoirs, drains, condensate outlets and compatible cooling-water circuits. Select bore for flow and wall thickness for routing, temperature and connection retention.
Food and beverage equipment
Specify a documented food-contact formulation for dispensing, filling and water lines. Match the grade to the food type, alcohol or fat content, contact time and cleaning process.
Laboratory and sampling equipment
Use transparent tubing for compatible liquid sampling, instrument connections and visual monitoring. Review adsorption, plasticizer extraction and contamination limits for sensitive samples.
Aquarium and aeration systems
Route low-pressure air or water where flexibility and visibility are useful. Confirm formulation suitability for the intended aquatic system and avoid unsupported bends that close the bore.
OEM machinery and appliances
Specify cut lengths, wall thickness, markings and packaging for assembly repeatability. Clear tubing helps maintenance teams locate bubbles, obstructions or discoloration.
Protection and rectangular profiles
Use custom rectangular or square hollow profiles for flat components, visible protective covers and guided routing. Fluid-carrying rectangular designs require their own sealing and deformation assessment.

Range at a glance
Round-tube enquiry sizes span 1–101.6 mm ID across separate metric and inch-based tables. Rectangular enquiry examples span 11 × 5 to 122 × 62.5 mm external dimensions. These are nominal selection geometries; confirm compound, tooling, tolerance and production availability for each order.
Material and technical specification
Flexible round tubing uses plasticized PVC. Rectangular tubing requires a separately selected flexible, semi-rigid or rigid clear PVC formulation to match the shape and application. The flexible-tube guidance below must not be transferred to rigid profiles. The agreed product specification defines the supplied grade and performance.
Technical item Selection and acceptance specification Строительство Single-wall clear PVC with no braid, textile reinforcement or wire helix. Flexible grade hardness Approximately 70–80 Shore A is a practical starting range; nominal value, tolerance and reading time are agreed by compound. Temperature planning 0 to +60°C is an initial selection envelope for general flexible service, not a universal rating. Specify colder conditions, elevated temperatures and exposure duration separately. Round dimensions ID × OD; nominal wall = (OD − ID) / 2. Metric and inch series are listed separately. Rectangular dimensions External width W × height H; nominal wall t; internal opening, corner radii, straightness and twist specified on the drawing. Working pressure Confirm a size-specific rating at actual temperature, including pump pulses and fitting limits. Specify required PSI, bar or MPa in the enquiry. Burst and proof testing Agree medium, conditioning, temperature, hold time, failure criteria and safety factor. Burst pressure is not an operating limit. Vacuum resistance Specify absolute pressure, temperature and duration; test collapse resistance in the installed bend. Bend radius Confirm for each round size; rectangular profiles need separate limits about their two bending axes. Dimensional tolerances Agree ID, OD or W/H, wall variation, ovality, corner radii and cut-length tolerances. Mechanical properties Specify tensile strength and elongation limits with the compound and test method; these do not establish finished-tube pressure capacity. Clarity and appearance Agree visual clarity, haze, surface finish, tint and acceptable extrusion marks using approved samples. Supply format Coils or cut lengths for flexible round tubing; profile lengths or coils according to rectangular rigidity and geometry. Pressure units and reporting
1 bar = 14.504 PSI; 1 MPa = 10 bar = 145.038 PSI. Record gauge or absolute pressure explicitly. A rating at 23°C cannot be applied unchanged at a higher temperature. Do not calculate a working-pressure claim from the dimension table alone.
Material and compliance options
Include plasticizer restrictions, food-contact requirements, RoHS or REACH documentation in the enquiry. Food-contact compliance, drinking-water approval, medical suitability and flame classification are separate requirements; they apply only to the documented grade and scope.
Metric round tubing size selection
Nominal metric sizes for quotation. Confirm the selected formulation, dimensional tolerance and length before order acceptance. The table does not assign a pressure or vacuum rating.
Inside diameter mm Outside diameter mm Nominal wall mm 1 2 0.5 2 3 0.5 3 6 1.5 4 6 1 5 8 1.5 6 9 1.5 8 11 1.5 8 12 2 8 14 3 9 12 1.5 10 13 1.5 10 16 3 12 15 1.5 12 16 2 12 18 3 15 18 1.5 15 19 2 16 19 1.5 16 20 2 16 22 3 18 23 2.5 19 22 1.5 22 27 2.5 22 28 3 25 31 3 32 38 3 32 42 5 38 44 3 38 48 5 50 59 4.5 50 61.5 5.75 60 72 6 Other bore and wall combinations can be reviewed against your drawing. For large diameters, include supports, minimum bend radius and suction conditions in the enquiry.
Inch and metric round tubing sizes
Inch fractions are nominal dimensions; millimetres are exact conversions rounded to 0.001 mm. Conversion precision is not a manufacturing tolerance. These sizes are quotation options, subject to production confirmation.
ID in ID mm OD in OD mm Wall mm 1/16 1.588 1/8 3.175 0.794 3/32 2.381 5/32 3.969 0.794 1/8 3.175 3/16 4.763 0.794 1/8 3.175 1/4 6.350 1.588 5/32 3.969 7/32 5.556 0.794 3/16 4.763 1/4 6.350 0.794 3/16 4.763 5/16 7.938 1.588 3/16 4.763 3/8 9.525 2.381 1/4 6.350 3/8 9.525 1.588 1/4 6.350 1/2 12.700 3.175 5/16 7.938 7/16 11.113 1.588 5/16 7.938 1/2 12.700 2.381 3/8 9.525 1/2 12.700 1.588 3/8 9.525 5/8 15.875 3.175 3/8 9.525 3/4 19.050 4.763 7/16 11.113 9/16 14.288 1.588 1/2 12.700 5/8 15.875 1.588 1/2 12.700 3/4 19.050 3.175 1/2 12.700 1 25.400 6.350 9/16 14.288 3/4 19.050 2.381 Match the fitting to the nominal series
A 1/4 in bore equals 6.350 mm; it is not identical to a 6 mm bore. Specify the dimension controlling the seal and retention, and select connectors for the actual flexible PVC compound and OD.
Inch and metric round tubing sizes continued
Inch fractions are nominal dimensions; millimetres are exact conversions rounded to 0.001 mm. Conversion precision is not a manufacturing tolerance. These sizes are quotation options, subject to production confirmation.
ID in ID mm OD in OD mm Wall mm 5/8 15.875 3/4 19.050 1.588 5/8 15.875 7/8 22.225 3.175 3/4 19.050 1 25.400 3.175 3/4 19.050 1 1/4 31.750 6.350 7/8 22.225 1 1/8 28.575 3.175 1 25.400 1 1/4 31.750 3.175 1 25.400 1 1/2 38.100 6.350 1 1/4 31.750 1 1/2 38.100 3.175 1 1/4 31.750 1 3/4 44.450 6.350 1 1/2 38.100 1 3/4 44.450 3.175 1 1/2 38.100 2 50.800 6.350 1 3/4 44.450 2 1/4 57.150 6.350 2 50.800 2 1/2 63.500 6.350 2 1/4 57.150 2 3/4 69.850 6.350 2 1/2 63.500 3 76.200 6.350 3 76.200 3 1/2 88.900 6.350 4 101.600 4 3/4 120.650 9.525 Large bore installation
The largest listed nominal combination is 4 in ID × 4 3/4 in OD (101.600 × 120.650 mm), with 9.525 mm wall. Large flexible tubing requires adequate support to avoid sagging, kinking and fitting loads. Select a reinforced or rigid construction separately when the required pressure or suction exceeds the qualified unreinforced design.
Length and packaging
State your required coil length or cut length, tolerance and packing method. Large bores and thick walls may need shorter coils or different packaging. Natural clear appearance can be specified against a sample; color tint and optical quality should be agreed before production.
Custom clear PVC rectangular tubing
Yozonetech can produce clear PVC rectangular tubing to an agreed drawing. Square profiles are also included in this family. Select the formulation around flexibility, optical appearance and dimensional stability; rigid or semi-rigid profiles are often more appropriate when the section must retain a defined shape.
The following external dimensions and walls are starting geometries for custom profile enquiries, not a stock list. Clear-material processing, corner design, tooling and achievable tolerances are confirmed separately. All dimensions below are in mm.
External width W External height H Nominal wall t 11 5 1 11 8 1 16 8 1 16 10 1 15 10 1 20 7 1 25 15 1 25 25 1 30 20 1 32 20 1 33 11 1.5 35 20 1.5 38.1 25.4 1 50 24 2 50 25 1.6 61 35.6 1 76 46 1.6 76 57 1.6 85 35 3 100 50 3 122 62.5 3 Define the internal opening and corners
For an ideal uniform wall, internal width is W − 2t and internal height is H − 2t. These values do not describe the clear opening at rounded corners. Specify inner and outer corner radii, mating-part clearance and a cross-section drawing. Square profiles have W = H.
Rectangular application limits
Rectangular flat walls can bulge under pressure and collapse under vacuum. Do not assign a circular-tube rating using an equivalent diameter. Pressure service, fluid connections, bending and sealing require validation of the actual rectangular assembly.
Selection installation and quality control
Choose the material for the medium
Specify fluid or gas composition, concentration and operating temperature. Review oils, fuels, solvents and cleaning chemicals individually. Standard clear flexible PVC is not a universal chemical hose; extraction, swelling and hardening can matter as much as immediate leakage.
Allow for temperature and ageing
Flexible PVC normally becomes stiffer in cold conditions and softer as temperature increases. Specify UV exposure, outdoor service and cleaning cycles. Inspect for hardening, discoloration, cracking, tackiness and permanent deformation.
Control pressure and vacuum
Use the approved operating rating for the complete assembly at temperature. Include surges and start-up conditions. Unreinforced clear tubing should not be assumed suitable for high-pressure compressed air, full vacuum or hydraulic service.
Install suitable connectors
Match the barb, ferrule or other connector to the tube dimensions and material. Avoid sharp edges, excessive stretching and overtightened clamps. Support large tubing and keep bends away from the fitting. Rectangular sections need purpose-designed seals or end connections.
Specify cleaning and contact requirements
Select a compatible cleaning agent and temperature. Do not assume steam or autoclave suitability. For food or water contact, define the intended medium, temperature and duration and obtain the applicable grade documentation.
Agree quality acceptance
For round tubing, inspect ID, OD, wall distribution, ovality and length. For rectangular profiles, add W/H, corner radii, straightness, twist and fit. Use approved samples for optical appearance and define any leak or pressure acceptance test.
Request a quotation
For round tubing, send ID × OD, length and tolerance. For rectangular tubing, send W × H × wall, internal opening, corner radii and rigidity requirement. Include medium, pressure or vacuum, temperature, annual quantity, sample quantity and required compliance documents.
Frequently asked questions
- What does unreinforced mean?
The tube wall contains no braid, textile layer or wire helix. Performance depends on the PVC formulation, dimensions and operating conditions.
- What round size range can I enquire about?
The combined tables span 1–101.6 mm ID. Sizes belong to separate metric and inch-based series; availability and performance are confirmed by order.
- Are inch and metric sizes interchangeable?
Not automatically. For example, 1/4 in equals 6.350 mm. Match the fitting to the actual nominal size and tolerance.
- Can you make clear rectangular PVC tubing?
Yes. Submit external width, height, wall, internal clearance, corner radii and required flexibility. The clear formulation and tooling are reviewed with the drawing.
- Is rectangular tubing the same as layflat hose?
No. Rectangular tubing is specified by a defined hollow profile. Layflat hose is normally flattened when unpressurized and uses a different dimensional convention.
- Can rectangular tubing carry pressurized fluid?
Only after the actual profile and connections are qualified. Flat-wall deformation and corner stresses prevent transfer of round-tube pressure ratings.
- Is all clear PVC food grade?
No. Clarity does not establish compliance. Specify the intended contact conditions and require documentation for the offered formulation.
- Can it handle fuel or strong solvents?
Suitability must be evaluated for the exact medium and temperature. A specialist formulation or a different material may be required.
- Can it be used for suction or compressed air?
Only within a validated assembly rating for the stated temperature and duty. For demanding suction or pressure, review a reinforced construction separately.
- Can lengths and optical appearance be customized?
Include cut length or coil length, tolerance, clarity, tint, marking and packaging in the enquiry. Final options are agreed for the selected profile and compound.

+86-13752771911