End Caps & Connectors
Product Overview
Purpose shaped products for cable ends stub splices and wire connections
Yozonetech heat shrink end caps and connectors cover cable-end and stub-splice sealing together with dedicated wire-connection insulation. Their closed-end or connector geometry requires separate size selection from straight heat shrink tubing.
Request a quote: ptfetube@yozonetech.cn

Product Selection
Select SBRS-DZ by wire range and connector dimensions. Select CAPS and CAPS NF by expanded diameter, recovered diameter, closed-end length and wall. CAPS NF is explicitly non-flame-retardant. CAPS-RL uses its own cable-range and dimensional table and a listed 3:1 ratio.
Product Range
SBRS-DZ — Heat-Shrink Insulation Connectors
SBRS-CAPS — Adhesive-Lined Insulating Caps
SBRS-CAPS NF — Semi-Rigid Adhesive-Lined Insulating Caps
SBRS-CAPS-RL — Semi-Rigid Adhesive-Lined Caps

How to Specify Your Requirement
Identify the model first, then compare the supplied dimensions, fully recovered dimensions and installation space. Specify operating conditions, required flame or halogen performance, color, length, quantity and packaging. Certification and test references apply to the stated model and must be matched to the supplied product.
Dimensions are in mm unless another unit is stated. Operating temperature, minimum shrink temperature, full-recovery temperature and aging-test conditions describe different requirements. Keep them separate when selecting and installing the product.
SBRS-DZ — Heat-Shrink Insulation Connectors
SBRS-DZ is a heat-shrink insulation connector construction for electrical connection protection. The source highlights visual seal confirmation, resistance to water, corrosive compounds and moisture, abrasion resistance, resistance to crimp-tool damage and splitting, adhesive bonding to plastics/rubbers/metals, and conformity to OEM wiring specifications. Continuous operating temperature is -45°C to 125°C; minimum shrinking temperature 80°C.
Technical data: tensile ≥14 MPa, typical 16 MPa; elongation ≥300%, typical 450%; aged tensile ≥7.3 MPa, typical 15 MPa; aged elongation ≥200%, typical 350%; dielectric strength ≥15 kV/mm, typical 17.5 kV/mm; volume resistivity ≥1×10^14 Ω·cm, typical 2.5×10^14 Ω·cm. Adhesive: water absorption <0.5%, softening point 95±5°C, peel 120 N/25 mm (PE) and 80 N/25 mm (AL).
Operating and Recovery Data
| Параметр | Catalog information |
| Operating temperature | −45°C to 125°C |
| Shrink or installation condition | 80°C minimum shrink temperature |
| Recovery ratio or product form | 4:1 |
Model features: Clear semi rigid adhesive lined tubing; Integral solderless splice connector; Visual inspection of the seal; Resistance to abrasion and splitting.
Размеры
| Code | Wire size (AWG) | Wire size (mm²) | Tube ID min (mm) | Recovered ID max (mm) | Length (mm) | Цвет | Package |
| SBRS-DZ-1 | 22−18 | 0.5−1.0 | 4.8 | 1.2 | 35.0 | red | 1000pc/bag |
| SBRS-DZ-2 | 16−14 | 1.5−2.5 | 5.5 | 1.4 | 35.0 | blue | 1000pc/bag |
| SBRS-DZ-3 | 12−10 | 4.0−6.0 | 6.5 | 1.5 | 42.0 | yellow | 500pc/bag |
Technical performance
| Недвижимость | Метод испытания | Standard | Typical performance |
| Tensile Strength(MPa) | ASTM D2671 | ≥14 | 16 |
| Elongation(%) | ASTM D2671 | ≥300 | 450 |
| Tensile Strength after aging (MPa) | UL 224, 158°C × 168 h | ≥7.3 | 15 |
| Elongation after aging(%) | UL 224, 158°C × 168 h | ≥200 | 350 |
| Dielectric strength(kV/mm) | IEC 60243 | ≥15 | 17.5 |
| Volume resistivity(Ω·cm) | IEC 60093 | ≥1×10¹⁴ | 2.5×10¹⁴ |
Adhesive properties
| Недвижимость | Метод испытания | Performance / requirement |
| Поглощение воды | ASTM D570 | ≤0,5% |
| Softening Point(°C) | ASTM E28 Es | 95±5 |
| Strength of peeling(PE) | ASTM D 1000 | 120N/25mm |
| Strength of peeling(AL) | ASTM D1000 | 80N/25mm |
SBRS-CAPS — Adhesive-Lined Insulating Caps
The SBRS-CAPS range uses 4:1 shrinkage and is intended for sealing and protecting cable ends and similar profiles against water, moisture and chemicals. The source lists continuous operating temperature -45°C to 125°C and minimum shrinking temperature 125°C.
Operating and Recovery Data
| Параметр | Catalog information |
| Operating temperature | −45°C to 125°C |
| Shrink or installation condition | 125°C minimum shrink temperature |
| Recovery ratio or product form | 4:1 |
Model features: End and stub splice protection; Bonds to PVC, XLPE and PP EPDM jackets; Moisture sealing for harnesses and electronic assemblies.
Размеры
| Code | Size (mm) | Standard length (mm) | Expanded ID min (mm) | Recovered ID max (mm) | Outer layer (mm) | Adhesive (mm) | Total wall (mm) |
| CAPS-1 | 3.2 | 22 | ≥5.72 | x1.27 | ≥0.64 | ≥0.56 | ≥1.20 |
| CAPS-2 | 4.8 | 25.4 | ≥7.44 | x1.65 | ≥0.76 | ≥0.76 | ≥1.52 |
| caps-3 | 6.4 | 28.4 | ≥10.85 | x2.41 | ≥0.89 | ≥1.37 | ≥1.91 |
Technical performance
| Недвижимость | Метод испытания | Standard | Typical performance |
| Tensile Strength(MPa) | ASTM D2671 | ≥10.4 | 11.5 |
| Elongation(%) | ASTM D2671 | ≥300 | 450 |
| Tensile Strength after aging (MPa) | UL 224, 158°C × 168 h | ≥7.3 | 8.5 |
| Elongation after aging(%) | UL 224, 158°C × 168 h | ≥200 | 350 |
| Dielectric strength(kV/mm) | IEC 60243 | ≥15 | 17.5 |
| Volume resistivity(Ω·cm) | IEC 60093 | ≥1×10¹⁴ | 2.5×10¹⁴ |
SBRS-CAPS NF — Semi-Rigid Adhesive-Lined Insulating Caps
The CAPS NF construction is semi-rigid and adhesive lined, with 4:1 shrinkage. The catalogue explicitly states that it is not flame-retardant. Continuous operating temperature is -45°C to 125°C and fully shrink temperature is 125°C.
Operating and Recovery Data
| Параметр | Catalog information |
| Operating temperature | −45°C to 125°C |
| Shrink or installation condition | 125°C |
| Recovery ratio or product form | 4:1 |
Model features: Semi rigid construction; End and stub splice protection; Not flame retardant; Bonds to PVC, XLPE and PP EPDM jackets.
Размеры
| Code | Size (mm) | Standard length (mm) | Expanded ID (mm) | Recovered ID (mm) | Outer layer (mm) | Adhesive (mm) | Total wall (mm) |
| CAPS NF-1 | 3.2 | 22 | 3.2 | 0.80 | 0.64 | 0.56 | 1.20 |
| CAPS NF-2 | 4.8 | 25.4 | 4.8 | 1.30 | 0.76 | 0.76 | 1.52 |
| CAPS NF-3 | 6.4 | 28.4 | 6.4 | 1.52 | 1.00 | 0.91 | 19.10 |
| CAPS NF-4 | 9.5 | 31.8 | 9.5 | 2.00 | 1.08 | 1.00 | 2.08 |
| CAPS NF-5 | 12.7 | 38.1 | 12.7 | 2.41 | 1.30 | 1.24 | 2.54 |
Technical performance
| Недвижимость | Метод испытания | Standard | Typical performance |
| Tensile Strength(MPa) | ASTM D2671 | ≥10.4 | 11.5 |
| Elongation(%) | ASTM D2671 | ≥300 | 450 |
| Tensile Strength after aging (MPa) | UL 224, 158°C × 168 h | ≥7.3 | 8.5 |
| Elongation after aging(%) | UL 224, 158°C × 168 h | ≥200 | 350 |
| Dielectric strength(kV/mm) | IEC 60243 | ≥15 | 17.5 |
| Volume resistivity(Ω·cm) | IEC 60093 | ≥1×10¹⁴ | 2.5×10¹⁴ |
SBRS-CAPS-RL — Semi-Rigid Adhesive-Lined Caps
SBRS-CAPS-RL is a larger-format semi-rigid cap with a 3:1 shrink ratio. The source describes resistance to common fluids and solvents, weathering and moisture contamination, a standard adhesive liner for environmental protection, heat-indicating lines and a coated hot-melt adhesive resistant to pull-off. Fully shrink temperature is 125°C and continuous operating temperature is -55°C to 110°C.
The catalogue's general technical data for this product family lists tensile strength ≥10.4 MPa, typical 11.5 MPa; elongation ≥300%, typical 450%; aged tensile ≥7.3 MPa, typical 8.5 MPa; aged elongation ≥200%, typical 350%; dielectric strength ≥15 kV/mm, typical 17.5 kV/mm; volume resistivity ≥1×10^14 Ω·cm, typical 2.5×10^14 Ω·cm. Adhesive: water absorption <0.2%, softening point 90±5°C, peel strength 120 N/25 mm (PE) and 80 N/25 mm (AL).
Operating and Recovery Data
| Параметр | Catalog information |
| Operating temperature | −55°C to 110°C |
| Shrink or installation condition | 125°C |
| Recovery ratio or product form | 3:1 |
Model features: Cable end and pipe or conduit sealing; Heat indicating lines; Hot melt adhesive lining; Resistance to weathering and common fluids; 600/1000 V rating stated in the catalog.
Metric dimensions
| Expanded length (mm) | Expanded ID min (mm) | Recovered ID max (mm) | Wall nominal (mm) | General use diameter (mm) | Cable range (AWG/MCM) |
| 50.80 | 10.20 | 3.80 | 2.00 | 4.5−8.5 | #8−#1 |
| 63.50 | 19.10 | 5.60 | 2.00 | 6−16.5 | #2−4/0 |
| 76.20 | 27.90 | 10.20 | 2.40 | 11.5−25 | 2/0−500 |
| 76.20 | 33.00 | 10.20 | 2.40 | 11.5−30 | 300−1000 |
| 88.90 | 38.10 | 12.70 | 2.40 | 14−35 | 500−1500 |
| 88.90 | 43.20 | 12.70 | 2.50 | 14−40 | 650−1750 |
| 88.90 | 52.10 | 19.00 | 2.50 | 21−45 | 900−2500 |
| 101.60 | 69.80 | 25.40 | 2.50 | 30−63 | 2000−2500 |
| 114.30 | 88.90 | 30.00 | 2.50 | 33−83.8 | — |
| 139.70 | 119.40 | 39.90 | 2.70 | 40.6−114.3 | — |
Inch dimensions
| Expanded length (in) | Expanded ID min (in) | Recovered ID max (in) | Wall nominal (in) | General use diameter (in) | Cable range (AWG/MCM) |
| 2.00 | 0.40 | 0.15 | 0.080 | 0.18−0.34 | #8−#1 |
| 2.50 | 0.75 | 0.22 | 0.080 | 0.24−0.65 | #2−4/0 |
| 3.00 | 1.10 | 0.40 | 0.095 | 0.45−1 | 2/0−500 |
| 3.00 | 1.30 | 0.40 | 0.095 | 0.45−1.2 | 300−1000 |
| 3.50 | 1.50 | 0.50 | 0.095 | 0.55−1.4 | 500−1500 |
| 3.50 | 1.70 | 0.50 | 0.100 | 0.55−1.6 | 650−1750 |
| 3.50 | 2.05 | 0.75 | 0.100 | 0.82−1.8 | 900−2500 |
| 4.00 | 2.75 | 1.00 | 0.100 | 1.2−2.5 | 2000−2500 |
| 4.50 | 3.50 | 1.18 | 0.100 | 1.3−3.3 | — |
| 5.50 | 4.70 | 1.57 | 0.105 | 1.6−4.5 | — |
Technical performance
| Недвижимость | Метод испытания | Standard | Typical performance |
| Tensile Strength(MPa) | ASTM D2671 | ≥10.4 | 11.5 |
| Elongation(%) | ASTM D2671 | ≥300 | 450 |
| Tensile Strength after aging (MPa) | UL 224, 158°C × 168 h | ≥7.3 | 8.5 |
| Elongation after aging(%) | UL 224, 158°C × 168 h | ≥200 | 350 |
| Dielectric strength(kV/mm) | IEC 60243 | ≥15 | 17.5 |
| Volume resistivity(Ω·cm) | IEC 60093 | ≥1×10¹⁴ | 2.5×10¹⁴ |
Adhesive properties
| Недвижимость | Метод испытания | Performance / requirement |
| Поглощение воды | ASTM D570 | ≤0.2% |
| Softening Point(°C) | ASTM E28 | 90±5 |
| Strength of peeling(PE) | ASTM D 1000 | 120N/25mm |
| Strength of peeling(AL) | ASTM D 1000 | 80N/25mm |
Applications and Installation
Typical use follows the selected model: wire and cable insulation, splice or component protection, environmental sealing, harness identification or specialty fluid exposure. Prepare and clean the substrate, protect heat-sensitive components and use controlled heating appropriate to the exact product. Check complete recovery and adhesive flow where applicable.
Frequently Asked Questions
Which model should I choose
Select SBRS-DZ by wire range and connector dimensions. Select CAPS and CAPS NF by expanded diameter, recovered diameter, closed-end length and wall. CAPS NF is explicitly non-flame-retardant. CAPS-RL uses its own cable-range and dimensional table and a listed 3:1 ratio.
Are all models flame retardant
Use the flame-performance statement of the exact model. Halogen-free, low-smoke and flame-retardant are separate requirements. A category title does not establish a shared rating.
How do I choose the size
Select the model and compare its supplied size with the largest assembly dimension and its recovered size with the required final fit. Check wall, tolerances, length and packaging in the corresponding table.
Is shrink temperature the operating temperature
No. Shrink or recovery temperature is an installation condition. Continuous operating temperature and short-duration laboratory aging or heat-shock tests are separate values.
Are all performance values guaranteed limits
Keep the distinction between standard requirements and typical test results shown in the tables. Agree the exact specification, acceptance limits, test method and product documentation with the order.
Can I order custom colors lengths or packaging
Send the exact model, dimensions, color, length, quantity and packaging requirements. Availability and nonstandard options are confirmed with the quotation.
Request a Quote
Send the model, required size, application, operating conditions, quantity, color and packaging. For markers, include print format and printer; for busbars, include voltage class and geometry; for caps and connectors, include cable or wire dimensions.
Электронная почта: ptfetube@yozonetech.cn
WhatsApp / Tel / WeChat: +86 13752771911
Website: www.chinaptfetube.com
+86-13752771911
E-mail:ptfetube@yozonetech.cn