Busbar Insulation Heat Shrink Tubing
Product Overview
Cross linked insulation sleeves for switchgear and substation busbars
Yozonetech busbar heat shrink tubing covers WMPG voltage-class series and RSFRNH-BTM medium-voltage tubing. Selection depends on busbar shape and dimensions, voltage class, recovered wall and the complete insulation-system design.
Request a quote: ptfetube@yozonetech.cn

Product Selection
Keep WMPG 1 kV, 10 kV, 20 kV and 35 kV series separate. For RSFRNH-BTM, select by the minimum supplied ID and maximum recovered ID, then check the listed recovered wall. A voltage label does not establish clearance, creepage or qualification of the complete switchgear assembly.
Product Range
WMPG — Heat Shrink Busbar Tube
RSFRNH-BTM — Medium Voltage Cross-Linked Polyolefin Bus-Bar Tubing
How to Specify Your Requirement
Identify the model first, then compare the supplied dimensions, fully recovered dimensions and installation space. Specify operating conditions, required flame or halogen performance, color, length, quantity and packaging. Certification and test references apply to the stated model and must be matched to the supplied product.
Dimensions are in mm unless another unit is stated. Operating temperature, minimum shrink temperature, full-recovery temperature and aging-test conditions describe different requirements. Keep them separate when selecting and installing the product.

WMPG — Heat Shrink Busbar Tube
WMPG is a cross-linked polyolefin heat-shrinkable busbar tube designed to provide insulation protection for busbars in switchgear and substations. The source describes protection against accidental flashover and leakage caused by small animals, reduction of busbar clearance requirements, and available yellow, red, green, blue and black colors.
Operating and Recovery Data
| Parâmetro | Catalog information |
| Operating temperature | See technical data |
| Shrink or installation condition | 70°C initial shrink; 125°C full recovery |
| Recovery ratio or product form | See dimensions |
Model features: Crosslinked polyolefin; Switchgear and substation busbar insulation; 1, 10, 20 and 35 kV selection tables; Yellow, red, green, blue and black.
10 kV WMPG dimensions
| Product number | Busbar width (mm) | Supplied ID min (mm) | Supplied wall (mm) | Recovered ID max (mm) | Recovered wall (mm) | Embalagem (m/rolo) |
| 10 kV WMPG 15/8 | 15/12 | 15.0±0.8 | 1.20±0.30 | ≤8 | 2.10±0.30 | 25 |
| 10 kV WMPG 20/10 | 20/15 | 20.0±0.8 | 1.20±0.30 | ≤10 | 2.10±0.30 | 25 |
| 10 kV WMPG 25/12 | 25/18 | 25.0±0.8 | 1.20±0.30 | ≤12.5 | 2.10±0.30 | 25 |
| 10 kV WMPG 30/15 | 32/20 | 30.0±0.8 | 1.20±0.30 | ≤15 | 2.10±0.30 | 25 |
| 10 kV WMPG 40/20 | 40/30 | 40.0±1.0 | 1.20±0.30 | ≤20 | 2.30±0.30 | 25 |
| 10 kV WMPG 50/25 | 50/35 | 50.0±3.0 | 1.20±0.30 | ≤25 | 2.30±0.30 | 25 |
| 10 kV WMPG 60/30 | 60/45 | 60.0±3.0 | 1.20±0.30 | ≤30 | 2.30±0.30 | 25 |
| 10 kV WMPG 65/33* | 65/45 | 65.0±3.0 | 1.20±0.30 | ≤33 | 2.30±0.30 | 25 |
| 10 kV WMPG 70/35 | 70/50 | 70.0±3.0 | 1.20±0.30 | ≤35 | 2.30±0.30 | 25 |
| 10 kV WMPG 75/38* | 75/50 | 75.0±3.0 | 1.20±0.30 | ≤38 | 2.30±0.30 | 25 |
| 10 kV WMPG 80/40 | 80/55 | 80.0±3.0 | 1.20±0.30 | ≤40 | 2.30±0.30 | 25 |
| 10 kV WMPG 85/43* | 80/65 | 85.0±3.0 | 1.20±0.30 | ≤43 | 2.40±0.30 | 25 |
| 10 kV WMPG 100/50 | 100/75 | 100.0±4.0 | 1.20±0.30 | ≤50 | 2.40±0.30 | 25 |
| 10 kV WMPG 120/60 | 120/85 | 120.0±4.0 | 1.20±0.30 | ≤60 | 2.40±0.30 | 25 |
| 10 kV WMPG 150/75 | 150/105 | 150.0±4.0 | 1.20±0.30 | ≤75 | 2.40±0.30 | 25 |
| 10 kV WMPG 180/90 | 180/120 | 180.0±5.0 | 1.20±0.30 | ≤90 | 2.40±0.30 | 25 |
| 10 kV WMPG 210/105* | 210/140 | 210.0±5.0 | 1.20±0.40 | ≤105 | 2.40±0.30 | 20 |
| 10 kV WMPG 230/115* | 230/150 | 230.0±5.0 | 1.20±0.40 | ≤115 | 2.40±0.30 | 20 |
| 10 kV WMPG 250/125* | 250/180 | 250.0±5.0 | 1.20±0.40 | ≤125 | 2.40±0.30 | 20 |
| 10 kV WMPG 300/150* | 300/210 | 300.0±5.0 | 1.20±0.40 | ≤150 | 2.40±0.30 | 15 |
1 kV WMPG dimensions
| Product number | Busbar width (mm) | Supplied ID min (mm) | Supplied wall (mm) | Recovered ID max (mm) | Recovered wall (mm) | Embalagem (m/rolo) |
| 1 kV WMPG 30 | 30 | 31.5±1.0 | 0.50±0.15 | ≤15 | 0.95±0.15 | 50 |
| 1 kV WMPG 35 | 35 | 36.5±1.5 | 0.50±0.15 | ≤18 | 1.00±0.15 | 50 |
| 1 kV WMPG 40 | 40 | 41.5±1.5 | 0.55±0.15 | ≤20 | 1.00±0.15 | 25 |
| 1 kV WMPG 45 | 45 | 41.5±1.5 | 0.55±0.15 | ≤23 | 1.00±0.15 | 25 |
| 1 kV WMPG 50 | 50 | 51.0±2.0 | 0.55±0.15 | ≤25 | 1.00±0.15 | 25 |
| 1 kV WMPG 60 | 60 | 60.0±3.0 | 0.60±0.20 | ≤30 | 1.30±0.20 | 25 |
| 1 kV WMPG 65* | 65 | 65.0±3.0 | 0.60±0.20 | ≤33 | 1.30±0.20 | 25 |
| 1 kV WMPG 70 | 70 | 70.0±3.0 | 0.65±0.20 | ≤35 | 1.30±0.20 | 25 |
| 1 kV WMPG 75* | 75 | 75.0±3.0 | 0.65±0.20 | ≤38 | 1.30±0.20 | 25 |
| 1 kV WMPG 80 | 80/100 | 80.0±3.0 | 0.65±0.20 | ≤40 | 1.46±0.20 | 25 |
| 1 kV WMPG 85* | 80/100 | 85.0±3.0 | 0.65±0.20 | ≤43 | 1.46±0.20 | 25 |
| 1 kV WMPG 90 | 100 | 90.0±4.0 | 0.65±0.20 | ≤45 | 1.46±0.20 | 25 |
| 1 kV WMPG 100 | 100/120 | 100.0±4.0 | 0.65±0.20 | ≤50 | 1.46±0.20 | 25 |
| 1 kV WMPG 120 | 150 | 120.0±4.0 | 0.65±0.20 | ≤60 | 1.46±0.20 | 25 |
| 1 kV WMPG 150 | 180 | 150.0±4.0 | 0.65±0.20 | ≤75 | 1.46±0.20 | 25 |
| 1 kV WMPG 180 | MAX | 180.0±4.0 | 0.65±0.20 | ≤90 | 1.46±0.20 | 25 |
| 1 kV WMPG 210* | MAX | 210.0±4.0 | 0.65±0.20 | ≤105 | 1.46±0.20 | 25 |
| 1 kV WMPG 230* | MAX | 230.0±4.0 | 0.65±0.20 | ≤115 | 1.46±0.20 | 25 |
| 1 kV WMPG 250* | MAX | 250.0±5.0 | 0.65±0.20 | ≤125 | 1.46±0.20 | 25 |
| 1 kV WMPG 300* | MAX | 300.0±5.0 | 0.65±0.20 | ≤150 | 1.46±0.20 | 25 |
35 kV WMPG dimensions
| Product number | Busbar width (mm) | Supplied ID min (mm) | Supplied wall (mm) | Recovered ID max (mm) | Recovered wall (mm) | Embalagem (m/rolo) |
| 35 kV WMPG 30/15 | 30 | 30.0±1.0 | 1.90±0.50 | ≤15 | 4.00±0.30 | 15 |
| 35 kV WMPG 35/18 | 30/40 | 35.0±1.0 | 1.90±0.50 | ≤18 | 4.00±0.30 | 15 |
| 35 kV WMPG 40/20 | 40 | 40.0±1.0 | 1.90±0.50 | ≤20 | 4.00±0.30 | 15 |
| 35 kV WMPG 50/25 | 50 | 50.0±2.0 | 1.90±0.50 | ≤25 | 4.00±0.30 | 15 |
| 35 kV WMPG 60/30 | 60 | 60.0±3.0 | 1.90±0.50 | ≤30 | 4.00±0.30 | 15 |
| 35 kV WMPG 65/33* | 60/70 | 65.0±3.0 | 1.90±0.50 | ≤33 | 4.00±0.30 | 15 |
| 35 kV WMPG 70/35 | 70 | 70.0±3.0 | 1.90±0.50 | ≤35 | 4.00±0.30 | 15 |
| 35 kV WMPG 75/38* | 70/80 | 75.0±3.0 | 1.90±0.50 | ≤38 | 4.00±0.30 | 15 |
| 35 kV WMPG 80/40 | 80/100 | 80.0±4.0 | 1.90±0.50 | ≤40 | 4.00±0.30 | 15 |
| 35 kV WMPG 100/50 | 100/120 | 100.0±4.0 | 1.90±0.50 | ≤50 | 4.00±0.30 | 15 |
| 35 kV WMPG 120/60 | 150 | 120.0±4.0 | 1.90±0.50 | ≤60 | 4.00±0.30 | 15 |
| 35 kV WMPG 150/75 | 180 | 150.0±4.0 | 1.90±0.50 | ≤75 | 4.00±0.30 | 15 |
| 35 kV WMPG 180/90* | MAX. | 180.0±5.0 | 1.90±0.50 | ≤90 | 4.00±0.30 | 15 |
| 35 kV WMPG 210/105* | MAX. | 210.0±5.0 | 1.90±0.50 | ≤105 | 4.00±0.30 | 15 |
| 35 kV WMPG 230/115* | MAX. | 230.0±5.0 | 1.90±0.50 | ≤115 | 4.00±0.30 | 15 |
| 35 kV WMPG 250/125* | MAX. | 250.0±5.0 | 1.90±0.50 | ≤125 | 4.00±0.30 | 15 |
| 35 kV WMPG 300/150* | MAX. | 300.0±5.0 | 1.90±0.50 | ≤150 | 4.00±0.30 | 15 |
20 kV WMPG dimensions
| Product number | Busbar width (mm) | Supplied ID min (mm) | Supplied wall (mm) | Recovered ID max (mm) | Recovered wall (mm) | Embalagem (m/rolo) |
| 20 kV WMPG 15/8 | 15/12 | 15.0±0.8 | 1.30±0.30 | ≤8 | 2.50±0.20 | 25 |
| 20 kV WMPG 20/10 | 20/15 | 20.0±0.8 | 1.30±0.30 | ≤10 | 2.50±0.20 | 25 |
| 20 kV WMPG 25/13 | 25/18 | 25.0±0.8 | 1.30±0.30 | ≤13 | 2.50±0.20 | 25 |
| 20 kV WMPG 30/15 | 32/20 | 30.0±0.8 | 1.30±0.30 | ≤15 | 2.50±0.20 | 25 |
| 20 kV WMPG 40/20 | 40/30 | 40.0±1.0 | 1.40±0.40 | ≤20 | 2.80±0.30 | 25 |
| 20 kV WMPG 50/25 | 50/35 | 50.0±2.0 | 1.40±0.40 | ≤25 | 2.80±0.30 | 25 |
| 20 kV WMPG 60/30 | 60/45 | 60.0±3.0 | 1.40±0.40 | ≤30 | 2.80±0.30 | 25 |
| 20 kV WMPG 65/33* | 65/45 | 65.0±3.0 | 1.40±0.40 | ≤33 | 2.80±0.30 | 25 |
| 20 kV WMPG 70/35 | 70/50 | 70.0±3.0 | 1.40±0.40 | ≤35 | 2.80±0.30 | 25 |
| 20 kV WMPG 75/38 | 75/50 | 75.0±3.0 | 1.40±0.40 | ≤38 | 2.80±0.30 | 25 |
| 20 kV WMPG 80/40 | 80/55 | 80.0±3.0 | 1.40±0.40 | ≤40 | 2.80±0.30 | 25 |
| 20 kV WMPG 85/43* | 80/65 | 85.0±3.0 | 1.40±0.40 | ≤43 | 2.80±0.30 | 25 |
| 20 kV WMPG 100/50 | 100/75 | 100.0±4.0 | 1.40±0.40 | ≤50 | 2.80±0.30 | 25 |
| 20 kV WMPG 120/60 | 120/85 | 120.0±4.0 | 1.40±0.40 | ≤60 | 2.80±0.30 | 25 |
| 20 kV WMPG 150/75 | 150/105 | 150.0±4.0 | 1.40±0.40 | ≤75 | 2.80±0.30 | 25 |
| 20 kV WMPG 180/90 | 180/120 | 180.0±5.0 | 1.40±0.40 | ≤90 | 2.80±0.30 | 25 |
| 20 kV WMPG 210/105* | 210/40 | 210.0±5.0 | 1.40±0.40 | ≤105 | 2.80±0.30 | 20 |
| 20 kV WMPG 230/115* | 230/150 | 230.0±5.0 | 1.40±0.40 | ≤115 | 2.80±0.30 | 20 |
Technical performance
| Imóveis | Método de ensaio | Performance / requirement |
| Resistência à tração | GB/T1040 | ≥8 MPa |
| Alongamento na rutura | GB/T 1040 | ≥300% |
| Tensile Strength after Aging | GB/T 1040, GB/T 7141 | >6.4MPa (130°C, 168 hrs) |
| Elongation at Break after Aging | GB/T 1040, GB/T 7141 | ≥100% (130°C, 168 h) |
| Hardness (Shore A) | ISO 868 | ≤90 |
| Resistência dieléctrica | IEC 60243 | ≥25kV/mm |
| Volume Resistivity | IEC 60093 | ≥1x10¹⁴Ω·cm |
| Constante dieléctrica | IEC 60250 | ≤3.0 |
| Longitudinal Shrinkage | ASTM-D-2671 | ≤10% |
| Eccentricity | ASTM-D-2671 | ≤30% (10 kV); ≤50% (35 kV) |
| Water Absorption | ISO 62 | ≤0.5% |
| Flammability (Oxygen Index) | ISO 4589 | ≥28 |
RSFRNH-BTM — Medium Voltage Cross-Linked Polyolefin Bus-Bar Tubing
Continuous operation is listed as -40°C to +110°C. The additional catalog statement about use at 175°C gives no duration or duty; obtain a confirmed specification before applying that temperature.
RSFRNH-BTM is made from specially formulated radiation cross-linked halogen-free compounds. The source states that it provides high resistance to tracking and arcing and improves busbar insulation in switchgear and substations. It is suitable for medium-voltage busbars, cable terminations and joints from 1 kV to 24 kV.
Operating and Recovery Data
| Parâmetro | Catalog information |
| Operating temperature | −40°C to 110°C continuous |
| Shrink or installation condition | 120°C |
| Recovery ratio or product form | See dimensions |
Model features: Halogen free radiation crosslinked compounds; Flame retardant; Resistance to tracking and arcing; Catalog describes 1 kV to 24 kV applications.
Dimensões
| Nominal size mm | Supplied ID min mm | Recovered ID max mm | Recovered wall mm | Standard length m/roll |
| 20/6 | 20 | 6 | 2.2 ± 0.3 | 25 |
| 28/9 | 28 | 9 | 2.6 ± 0.3 | 25 |
| 33/10 | 33 | 10 | 2.8 ± 0.3 | 25 |
| 40/12 | 40 | 12 | 2.8 ± 0.3 | 25 |
| 45/14 | 45 | 14 | 3.0 ± 0.3 | 25 |
| 55/16 | 55 | 16 | 3.0 ± 0.3 | 25 |
| 65/19 | 65 | 19 | 3.0 ± 0.3 | 25 |
| 75/22 | 75 | 22 | 3.0 ± 0.3 | 25 |
| 85/25 | 85 | 25 | 3.2 ± 0.3 | 25 |
| 95/30 | 95 | 30 | 3.2 ± 0.3 | 25 |
| 115/34 | 115 | 34 | 3.3 ± 0.3 | 25 |
| 130/36 | 130 | 36 | 3.3 ± 0.3 | 25 |
| 160/50 | 160 | 50 | 3.3 ± 0.3 | 25 |
| 180/56 | 180 | 56 | 3.3 ± 0.3 | 25 |
Physical performance
| Imóveis | Método de ensaio | Standard | Typical performance |
| Resistência à tração | IEC 60684 | ≥8 MPa | 10.5 Mpa |
| Alongamento | IEC 60684 | ≥400% | 550% |
| Heat Aging tensile strength | 150°Cx168h | ≥5 MPa | 9.5 Mpa |
| Aging elongation Heat | 150°Cx168h | ≥200% | 450% |
| Heat shock | 225°Cx4h | no cracking or flowing | no cracking or flowing |
| Flammability | ASTM D2671B | Self extinguishing within 30 s | Self extinguishing within 30 s |
| Low temperature Flexibility | −40°Cx4h | no cracking | no cracking |
Electrical performance
| Imóveis | Método de ensaio | Standard | Typical performance |
| Resistência dieléctrica | IEC 60684 | ≥20KV/mm | 23kv/mm |
| Volume Resistivity | IEC 60684 | ≥1x10¹³Ω·cm | 2x10¹⁴Ω·cm |
| Tracking(2.5kv,60min) | IEC 60684 | no cracking | no cracking |
Applications and Installation
Use the selected voltage-class product as part of an engineered switchgear or busbar insulation system. Confirm busbar geometry, clearance, creepage and recovered-wall requirements; model voltage labels and laboratory values do not certify the finished assembly.
Frequently Asked Questions
Which model should I choose
Keep WMPG 1 kV, 10 kV, 20 kV and 35 kV series separate. For RSFRNH-BTM, select by the minimum supplied ID and maximum recovered ID, then check the listed recovered wall. A voltage label does not establish clearance, creepage or qualification of the complete switchgear assembly.
Are all models flame retardant
Use the flame-performance statement of the exact model. Halogen-free, low-smoke and flame-retardant are separate requirements. A category title does not establish a shared rating.
How do I choose the size
Select the model and compare its supplied size with the largest assembly dimension and its recovered size with the required final fit. Check wall, tolerances, length and packaging in the corresponding table.
Is shrink temperature the operating temperature
No. Shrink or recovery temperature is an installation condition. Continuous operating temperature and short-duration laboratory aging or heat-shock tests are separate values.
Are all performance values guaranteed limits
Keep the distinction between standard requirements and typical test results shown in the tables. Agree the exact specification, acceptance limits, test method and product documentation with the order.
Can I order custom colors lengths or packaging
Send the exact model, dimensions, color, length, quantity and packaging requirements. Availability and nonstandard options are confirmed with the quotation.
Request a Quote
Send the model, required size, application, operating conditions, quantity, color and packaging. For markers, include print format and printer; for busbars, include voltage class and geometry; for caps and connectors, include cable or wire dimensions.
Correio eletrónico: ptfetube@yozonetech.cn
WhatsApp / Tel / WeChat: +86 13752771911
Website: www.chinaptfetube.com
+86-13752771911
E-mail:ptfetube@yozonetech.cn