• Inicio
  • Busbar Insulation Heat Shrink Tubing

Busbar Insulation Heat Shrink Tubing

Yozonetech busbar heat shrink tubing provides insulation protection for busbars used in switchgear and substations. The product range includes WMPG voltage-class tubing and RSFRNH-BTM medium-voltage tubing, with different sizes and recovered wall thicknesses for application-specific selection.

✔ Multiple Voltage Classes: WMPG series options include 1 kV, 10 kV, 20 kV and 35 kV. RSFRNH-BTM is listed for applications from 1 kV to 24 kV.

✔ Electrical Insulation Protection: Helps protect busbars against accidental flashover, tracking and arcing, depending on the selected product.

✔ Material Options: WMPG uses cross-linked polyolefin, while RSFRNH-BTM uses radiation cross-linked, halogen-free compounds and is flame-retardant.

✔ Size and Color Selection: Choose according to busbar geometry, supplied and recovered diameters, recovered wall thickness, voltage class and installation requirements. WMPG is available in yellow, red, green, blue and black.

Detalle del producto

Product Overview

Cross linked insulation sleeves for switchgear and substation busbars

Yozonetech busbar heat shrink tubing covers WMPG voltage-class series and RSFRNH-BTM medium-voltage tubing. Selection depends on busbar shape and dimensions, voltage class, recovered wall and the complete insulation-system design.

Request a quote: ptfetube@yozonetech.cn

Busbar Insulation Heat Shrink Tubing

Product Selection

Keep WMPG 1 kV, 10 kV, 20 kV and 35 kV series separate. For RSFRNH-BTM, select by the minimum supplied ID and maximum recovered ID, then check the listed recovered wall. A voltage label does not establish clearance, creepage or qualification of the complete switchgear assembly.

Product Range

WMPG — Heat Shrink Busbar Tube

RSFRNH-BTM — Medium Voltage Cross-Linked Polyolefin Bus-Bar Tubing

How to Specify Your Requirement

Identify the model first, then compare the supplied dimensions, fully recovered dimensions and installation space. Specify operating conditions, required flame or halogen performance, color, length, quantity and packaging. Certification and test references apply to the stated model and must be matched to the supplied product.

Dimensions are in mm unless another unit is stated. Operating temperature, minimum shrink temperature, full-recovery temperature and aging-test conditions describe different requirements. Keep them separate when selecting and installing the product.

Busbar Insulation Heat Shrink Tubing

WMPG — Heat Shrink Busbar Tube

WMPG is a cross-linked polyolefin heat-shrinkable busbar tube designed to provide insulation protection for busbars in switchgear and substations. The source describes protection against accidental flashover and leakage caused by small animals, reduction of busbar clearance requirements, and available yellow, red, green, blue and black colors.

Operating and Recovery Data

Parámetro Catalog information
Operating temperature See technical data
Shrink or installation condition 70°C initial shrink; 125°C full recovery
Recovery ratio or product form See dimensions

Model features: Crosslinked polyolefin; Switchgear and substation busbar insulation; 1, 10, 20 and 35 kV selection tables; Yellow, red, green, blue and black.

10 kV WMPG dimensions

Product number Busbar width (mm) Supplied ID min (mm) Supplied wall (mm) Recovered ID max (mm) Recovered wall (mm) Package (m/roll)
10 kV WMPG 15/8 15/12 15.0±0.8 1.20±0.30 ≤8 2.10±0.30 25
10 kV WMPG 20/10 20/15 20.0±0.8 1.20±0.30 ≤10 2.10±0.30 25
10 kV WMPG 25/12 25/18 25.0±0.8 1.20±0.30 ≤12.5 2.10±0.30 25
10 kV WMPG 30/15 32/20 30.0±0.8 1.20±0.30 ≤15 2.10±0.30 25
10 kV WMPG 40/20 40/30 40.0±1.0 1.20±0.30 ≤20 2.30±0.30 25
10 kV WMPG 50/25 50/35 50.0±3.0 1.20±0.30 ≤25 2.30±0.30 25
10 kV WMPG 60/30 60/45 60.0±3.0 1.20±0.30 ≤30 2.30±0.30 25
10 kV WMPG 65/33* 65/45 65.0±3.0 1.20±0.30 ≤33 2.30±0.30 25
10 kV WMPG 70/35 70/50 70.0±3.0 1.20±0.30 ≤35 2.30±0.30 25
10 kV WMPG 75/38* 75/50 75.0±3.0 1.20±0.30 ≤38 2.30±0.30 25
10 kV WMPG 80/40 80/55 80.0±3.0 1.20±0.30 ≤40 2.30±0.30 25
10 kV WMPG 85/43* 80/65 85.0±3.0 1.20±0.30 ≤43 2.40±0.30 25
10 kV WMPG 100/50 100/75 100.0±4.0 1.20±0.30 ≤50 2.40±0.30 25
10 kV WMPG 120/60 120/85 120.0±4.0 1.20±0.30 ≤60 2.40±0.30 25
10 kV WMPG 150/75 150/105 150.0±4.0 1.20±0.30 ≤75 2.40±0.30 25
10 kV WMPG 180/90 180/120 180.0±5.0 1.20±0.30 ≤90 2.40±0.30 25
10 kV WMPG 210/105* 210/140 210.0±5.0 1.20±0.40 ≤105 2.40±0.30 20
10 kV WMPG 230/115* 230/150 230.0±5.0 1.20±0.40 ≤115 2.40±0.30 20
10 kV WMPG 250/125* 250/180 250.0±5.0 1.20±0.40 ≤125 2.40±0.30 20
10 kV WMPG 300/150* 300/210 300.0±5.0 1.20±0.40 ≤150 2.40±0.30 15

1 kV WMPG dimensions

Product number Busbar width (mm) Supplied ID min (mm) Supplied wall (mm) Recovered ID max (mm) Recovered wall (mm) Package (m/roll)
1 kV WMPG 30 30 31.5±1.0 0.50±0.15 ≤15 0.95±0.15 50
1 kV WMPG 35 35 36.5±1.5 0.50±0.15 ≤18 1.00±0.15 50
1 kV WMPG 40 40 41.5±1.5 0.55±0.15 ≤20 1.00±0.15 25
1 kV WMPG 45 45 41.5±1.5 0.55±0.15 ≤23 1.00±0.15 25
1 kV WMPG 50 50 51.0±2.0 0.55±0.15 ≤25 1.00±0.15 25
1 kV WMPG 60 60 60.0±3.0 0.60±0.20 ≤30 1.30±0.20 25
1 kV WMPG 65* 65 65.0±3.0 0.60±0.20 ≤33 1.30±0.20 25
1 kV WMPG 70 70 70.0±3.0 0.65±0.20 ≤35 1.30±0.20 25
1 kV WMPG 75* 75 75.0±3.0 0.65±0.20 ≤38 1.30±0.20 25
1 kV WMPG 80 80/100 80.0±3.0 0.65±0.20 ≤40 1.46±0.20 25
1 kV WMPG 85* 80/100 85.0±3.0 0.65±0.20 ≤43 1.46±0.20 25
1 kV WMPG 90 100 90.0±4.0 0.65±0.20 ≤45 1.46±0.20 25
1 kV WMPG 100 100/120 100.0±4.0 0.65±0.20 ≤50 1.46±0.20 25
1 kV WMPG 120 150 120.0±4.0 0.65±0.20 ≤60 1.46±0.20 25
1 kV WMPG 150 180 150.0±4.0 0.65±0.20 ≤75 1.46±0.20 25
1 kV WMPG 180 MAX 180.0±4.0 0.65±0.20 ≤90 1.46±0.20 25
1 kV WMPG 210* MAX 210.0±4.0 0.65±0.20 ≤105 1.46±0.20 25
1 kV WMPG 230* MAX 230.0±4.0 0.65±0.20 ≤115 1.46±0.20 25
1 kV WMPG 250* MAX 250.0±5.0 0.65±0.20 ≤125 1.46±0.20 25
1 kV WMPG 300* MAX 300.0±5.0 0.65±0.20 ≤150 1.46±0.20 25

35 kV WMPG dimensions

Product number Busbar width (mm) Supplied ID min (mm) Supplied wall (mm) Recovered ID max (mm) Recovered wall (mm) Package (m/roll)
35 kV WMPG 30/15 30 30.0±1.0 1.90±0.50 ≤15 4.00±0.30 15
35 kV WMPG 35/18 30/40 35.0±1.0 1.90±0.50 ≤18 4.00±0.30 15
35 kV WMPG 40/20 40 40.0±1.0 1.90±0.50 ≤20 4.00±0.30 15
35 kV WMPG 50/25 50 50.0±2.0 1.90±0.50 ≤25 4.00±0.30 15
35 kV WMPG 60/30 60 60.0±3.0 1.90±0.50 ≤30 4.00±0.30 15
35 kV WMPG 65/33* 60/70 65.0±3.0 1.90±0.50 ≤33 4.00±0.30 15
35 kV WMPG 70/35 70 70.0±3.0 1.90±0.50 ≤35 4.00±0.30 15
35 kV WMPG 75/38* 70/80 75.0±3.0 1.90±0.50 ≤38 4.00±0.30 15
35 kV WMPG 80/40 80/100 80.0±4.0 1.90±0.50 ≤40 4.00±0.30 15
35 kV WMPG 100/50 100/120 100.0±4.0 1.90±0.50 ≤50 4.00±0.30 15
35 kV WMPG 120/60 150 120.0±4.0 1.90±0.50 ≤60 4.00±0.30 15
35 kV WMPG 150/75 180 150.0±4.0 1.90±0.50 ≤75 4.00±0.30 15
35 kV WMPG 180/90* MAX. 180.0±5.0 1.90±0.50 ≤90 4.00±0.30 15
35 kV WMPG 210/105* MAX. 210.0±5.0 1.90±0.50 ≤105 4.00±0.30 15
35 kV WMPG 230/115* MAX. 230.0±5.0 1.90±0.50 ≤115 4.00±0.30 15
35 kV WMPG 250/125* MAX. 250.0±5.0 1.90±0.50 ≤125 4.00±0.30 15
35 kV WMPG 300/150* MAX. 300.0±5.0 1.90±0.50 ≤150 4.00±0.30 15

20 kV WMPG dimensions

Product number Busbar width (mm) Supplied ID min (mm) Supplied wall (mm) Recovered ID max (mm) Recovered wall (mm) Package (m/roll)
20 kV WMPG 15/8 15/12 15.0±0.8 1.30±0.30 ≤8 2.50±0.20 25
20 kV WMPG 20/10 20/15 20.0±0.8 1.30±0.30 ≤10 2.50±0.20 25
20 kV WMPG 25/13 25/18 25.0±0.8 1.30±0.30 ≤13 2.50±0.20 25
20 kV WMPG 30/15 32/20 30.0±0.8 1.30±0.30 ≤15 2.50±0.20 25
20 kV WMPG 40/20 40/30 40.0±1.0 1.40±0.40 ≤20 2.80±0.30 25
20 kV WMPG 50/25 50/35 50.0±2.0 1.40±0.40 ≤25 2.80±0.30 25
20 kV WMPG 60/30 60/45 60.0±3.0 1.40±0.40 ≤30 2.80±0.30 25
20 kV WMPG 65/33* 65/45 65.0±3.0 1.40±0.40 ≤33 2.80±0.30 25
20 kV WMPG 70/35 70/50 70.0±3.0 1.40±0.40 ≤35 2.80±0.30 25
20 kV WMPG 75/38 75/50 75.0±3.0 1.40±0.40 ≤38 2.80±0.30 25
20 kV WMPG 80/40 80/55 80.0±3.0 1.40±0.40 ≤40 2.80±0.30 25
20 kV WMPG 85/43* 80/65 85.0±3.0 1.40±0.40 ≤43 2.80±0.30 25
20 kV WMPG 100/50 100/75 100.0±4.0 1.40±0.40 ≤50 2.80±0.30 25
20 kV WMPG 120/60 120/85 120.0±4.0 1.40±0.40 ≤60 2.80±0.30 25
20 kV WMPG 150/75 150/105 150.0±4.0 1.40±0.40 ≤75 2.80±0.30 25
20 kV WMPG 180/90 180/120 180.0±5.0 1.40±0.40 ≤90 2.80±0.30 25
20 kV WMPG 210/105* 210/40 210.0±5.0 1.40±0.40 ≤105 2.80±0.30 20
20 kV WMPG 230/115* 230/150 230.0±5.0 1.40±0.40 ≤115 2.80±0.30 20

Technical performance

Propiedad Método de ensayo Performance / requirement
Resistencia a la tracción GB/T1040 ≥8 MPa
Alargamiento a la rotura GB/T 1040 ≥300%
Tensile Strength after Aging GB/T 1040, GB/T 7141 >6.4MPa (130°C, 168 hrs)
Alargamiento a la rotura tras el envejecimiento GB/T 1040, GB/T 7141 ≥100% (130°C, 168 h)
Hardness (Shore A) ISO 868 ≤90
Rigidez dieléctrica IEC 60243 ≥25kV/mm
Resistividad volumétrica IEC 60093 ≥1x10¹⁴Ω·cm
Constante dieléctrica IEC 60250 ≤3.0
Longitudinal Shrinkage ASTM-D-2671 ≤10%
Eccentricity ASTM-D-2671 ≤30% (10 kV); ≤50% (35 kV)
Absorción de agua ISO 62 ≤0.5%
Flammability (Oxygen Index) ISO 4589 ≥28

RSFRNH-BTM — Medium Voltage Cross-Linked Polyolefin Bus-Bar Tubing

Continuous operation is listed as -40°C to +110°C. The additional catalog statement about use at 175°C gives no duration or duty; obtain a confirmed specification before applying that temperature.

RSFRNH-BTM is made from specially formulated radiation cross-linked halogen-free compounds. The source states that it provides high resistance to tracking and arcing and improves busbar insulation in switchgear and substations. It is suitable for medium-voltage busbars, cable terminations and joints from 1 kV to 24 kV.

Operating and Recovery Data

Parámetro Catalog information
Operating temperature −40°C to 110°C continuous
Shrink or installation condition 120°C
Recovery ratio or product form See dimensions

Model features: Halogen free radiation crosslinked compounds; Flame retardant; Resistance to tracking and arcing; Catalog describes 1 kV to 24 kV applications.

Dimensiones

Nominal size mm Supplied ID min mm Recovered ID max mm Recovered wall mm Standard length m/roll
20/6 20 6 2.2 ± 0.3 25
28/9 28 9 2.6 ± 0.3 25
33/10 33 10 2.8 ± 0.3 25
40/12 40 12 2.8 ± 0.3 25
45/14 45 14 3.0 ± 0.3 25
55/16 55 16 3.0 ± 0.3 25
65/19 65 19 3.0 ± 0.3 25
75/22 75 22 3.0 ± 0.3 25
85/25 85 25 3.2 ± 0.3 25
95/30 95 30 3.2 ± 0.3 25
115/34 115 34 3.3 ± 0.3 25
130/36 130 36 3.3 ± 0.3 25
160/50 160 50 3.3 ± 0.3 25
180/56 180 56 3.3 ± 0.3 25

Physical performance

Propiedad Método de ensayo Standard Typical performance
Resistencia a la tracción IEC 60684 ≥8 MPa 10.5 Mpa
Alargamiento IEC 60684 ≥400% 550%
Heat Aging tensile strength 150°Cx168h ≥5 MPa 9.5 Mpa
Aging elongation Heat 150°Cx168h ≥200% 450%
Heat shock 225°Cx4h no cracking or flowing no cracking or flowing
Inflamabilidad ASTM D2671B Self extinguishing within 30 s Self extinguishing within 30 s
Low temperature Flexibility −40°Cx4h no cracking no cracking

Electrical performance

Propiedad Método de ensayo Standard Typical performance
Rigidez dieléctrica IEC 60684 ≥20KV/mm 23kv/mm
Resistividad volumétrica IEC 60684 ≥1x10¹³Ω·cm 2x10¹⁴Ω·cm
Tracking(2.5kv,60min) IEC 60684 no cracking no cracking

Applications and Installation

Use the selected voltage-class product as part of an engineered switchgear or busbar insulation system. Confirm busbar geometry, clearance, creepage and recovered-wall requirements; model voltage labels and laboratory values do not certify the finished assembly.

Preguntas frecuentes

Which model should I choose

Keep WMPG 1 kV, 10 kV, 20 kV and 35 kV series separate. For RSFRNH-BTM, select by the minimum supplied ID and maximum recovered ID, then check the listed recovered wall. A voltage label does not establish clearance, creepage or qualification of the complete switchgear assembly.

Are all models flame retardant

Use the flame-performance statement of the exact model. Halogen-free, low-smoke and flame-retardant are separate requirements. A category title does not establish a shared rating.

How do I choose the size

Select the model and compare its supplied size with the largest assembly dimension and its recovered size with the required final fit. Check wall, tolerances, length and packaging in the corresponding table.

Is shrink temperature the operating temperature

No. Shrink or recovery temperature is an installation condition. Continuous operating temperature and short-duration laboratory aging or heat-shock tests are separate values.

Are all performance values guaranteed limits

Keep the distinction between standard requirements and typical test results shown in the tables. Agree the exact specification, acceptance limits, test method and product documentation with the order.

Can I order custom colors lengths or packaging

Send the exact model, dimensions, color, length, quantity and packaging requirements. Availability and nonstandard options are confirmed with the quotation.

Request a Quote

Send the model, required size, application, operating conditions, quantity, color and packaging. For markers, include print format and printer; for busbars, include voltage class and geometry; for caps and connectors, include cable or wire dimensions.

Correo electrónico: ptfetube@yozonetech.cn
WhatsApp / Tel / WeChat: +86 13752771911
Website: www.chinaptfetube.com

Deje su mensaje