PFA 100% Tubo extruido transparente virgen Proveedores OEM para semiconductores
Product Overview
Metric and inch PFA tubing for chemical semiconductor and industrial fluid handling
PFA tubing is extruded from perfluoroalkoxy fluoropolymer for demanding fluid-handling, chemical-processing, semiconductor, laboratory and industrial applications. It combines broad chemical resistance and thermal stability with a clear or translucent appearance and melt processability. These properties make it useful where clean fluid paths, visual inspection and consistent tube geometry matter.
Yozonetech supplies standard metric and inch tubing, with custom inner diameter, outer diameter, wall thickness and length available for review. Suitable dimensions can be supplied in coils or straight lengths. For high-purity service, define the resin grade, processing controls, cleanliness and packaging requirements together.
![]()
Why Choose PFA Tubing?
| Rendimiento | Engineering / Application Value |
| High Purity | Suitable for fluid systems where contamination control and material cleanliness are important; exact grade and processing requirements should be specified. |
| Excellent Chemical Resistance | Resists a broad range of aggressive chemicals and process media; compatibility should be verified for the exact medium, concentration and temperature. |
| High Transparency | The clear or translucent appearance can support visual monitoring of fluid condition, flow and contamination in suitable systems. |
| High-Temperature Stability | Maintains useful performance in demanding thermal environments; actual operating limits depend on grade, dimensions, pressure and service conditions. |
| Smooth Internal Surface | Supports low-adhesion fluid pathways and helps reduce locations where process residues may accumulate. |
| Low Moisture Absorption | Helps maintain stable material behavior in humid or wet environments. |
| Melt-Processable Fluoropolymer | PFA can be processed by melt-extrusion methods, enabling consistent tubing production and complex fluoropolymer constructions. |
| Low Extractables / Clean Fluid Handling | Appropriate PFA grades are commonly considered where fluid purity and low contamination are critical; final suitability must be verified for the application. |
PFA also provides electrical insulating properties and low moisture absorption. Define the required electrical, environmental and cleanliness performance for the supplied tube and complete installation.
PFA Tube Product Range
| Product Type | Typical Positioning |
| Standard PFA Tube | General-purpose PFA tubing for chemical, laboratory, industrial and fluid-handling systems. |
| High-Purity PFA Tube | Selected grades and controlled processing for demanding cleanliness and contamination-control requirements. |
| Transparent PFA Tube | Clear tubing where visual inspection of flow, bubbles or fluid condition is useful. |
| Thin-Wall PFA Tube | Compact tubing for instrumentation, analytical equipment and applications where reduced wall thickness is appropriate. |
| Thick-Wall PFA Tube | Higher-wall construction for greater mechanical robustness; pressure suitability must be confirmed for the exact dimensions. |
| Small-Bore PFA Tube | Small-ID tubing for instrumentation, sampling, reagent delivery and compact fluid paths. |
| Custom PFA Tube | Application-specific ID, OD, wall thickness, length, packaging or other agreed requirements. |
| Special PFA Constructions | Special configurations may be evaluated for application-specific routing, purity or assembly requirements. |
Aplicaciones
| Industria | Typical Uses |
| Semiconductor & Electronics | High-purity chemical delivery, wet-process equipment, reagent lines, instrumentation and clean fluid pathways. |
| Chemical Processing | Corrosive chemical transfer, sampling, reagent handling, process lines and laboratory systems. |
| Pharmaceutical & Bioprocess | High-purity fluid pathways and process tubing where the specified grade and documentation meet the application requirements. |
| Laboratory & Analytical Equipment | Sampling lines, reagent delivery, instrument connections and transparent process paths. |
| Medical / Life Science | Selected fluid-management applications subject to exact material, cleanliness and regulatory requirements. |
| Food & Beverage | Suitable fluid-contact applications where the exact PFA grade meets the required compliance standard. |
| Equipamiento industrial | Chemical-resistant fluid routing, pump connections, instrumentation and protective tubing. |
| Electrical / High-Voltage | Selected insulation and protective applications requiring fluoropolymer electrical performance. |
For food-contact, pharmaceutical, medical or other regulated applications, confirm the exact material grade, product qualification and required documentation before ordering. Application names describe potential uses; suitability depends on the supplied product and service conditions.
Metric Dimensions
DKP series. Standard series length: 100 m. Dimensions are outer diameter × inner diameter in millimeters.
| Modelo | OD × ID (mm) | Pressure group |
| DKP-0201 | 2 × 1 | A |
| DKP-0302 | 3 × 2 | C |
| DKP-0425 | 4 × 2.5 | B |
| DKP-0403 | 4 × 3 | D |
| DKP-0604 | 6 × 4 | C |
| DKP-0806 | 8 × 6 | D |
| DKP-1075 | 10 × 7.5 | D |
| DKP-1008 | 10 × 8 | E |
| DKP-1209 | 12 × 9 | D |
| DKP-1210 | 12 × 10 | F |
| DKP-1613 | 16 × 13 | E |
| DKP-1916 | 19 × 16 | F |
| DKP-2522 | 25 × 22 | G |
Listed metric sizes range from 2 × 1 mm to 25 × 22 mm. Standard PFA tubing is separate from the conductive-strip construction offered as Anti-Static PFA Tubing.
Metric Maximum Operating Pressure
Maximum operating pressure in MPa at the stated temperature. Match the complete model to its group.
| Group | Models | 20°C | 100°C | 200°C | 260°C |
| A | DKP-0201 | 2.3 | 1.1 | 0.55 | 0.3 |
| B | DKP-0425 | 1.7 | 0.9 | 0.45 | 0.23 |
| C | DKP-0302, DKP-0604 | 1.5 | 0.7 | 0.35 | 0.2 |
| D | DKP-0403, DKP-0806, DKP-1075, DKP-1209 | 1 | 0.5 | 0.25 | 0.15 |
| E | DKP-1008, DKP-1613 | 0.7 | 0.35 | 0.17 | 0.11 |
| F | DKP-1210, DKP-1916 | 0.6 | 0.3 | 0.15 | 0.1 |
| G | DKP-2522 | 0.4 | 0.2 | 0.1 | 0.05 |
![]()
Seven groups are shown. The vertical axis represents maximum operating pressure from 0 to 2.5 MPa; the horizontal axis represents temperature. Curves connect the tabulated reference points; intermediate-temperature ratings require confirmation.
Operating Index
| Artículo | Especificación |
| Using fluids | Air, water and inert gas |
| Maximum operating pressure | Refer to the model-specific pressure table and curve |
| Maximum operating temperature | 260°C |
| Material | PFA resin |
The temperature limit and pressure rating must be considered together. Confirm the allowable working conditions of both tubing and fittings for the installation.
Inch Dimensions
DKIP series. Standard series length: 100 m. All inch and millimeter values below retain the source values.
| Dimension | DKIP-1 | DKIP-2 | DKIP-3 | DKIP-4 | DKIP-5 | DKIP-6 | DKIP-7 | DKIP-8 | DKIP-9 |
| OD (inch) | 1/8 | 1/8 | 3/16 | 1/4 | 3/8 | 1/2 | 3/4 | 1 | 1-1/4 |
| OD (mm) | 3.18 | 3.18 | 4.75 | 6.35 | 9.53 | 12.7 | 19.05 | 25.4 | 31.75 |
| ID (inch) | 0.086 | 1/16 | 1/8 | 5/32 | 1/4 | 3/8 | 5/8 | 7/8 | 11/10 |
| ID (mm) | 2.18 | 1.58 | 3.15 | 3.95 | 6.33 | 9.5 | 15.85 | 22.2 | 27.95 |
Inch Maximum Operating Pressure
| Group | Models | 20°C | 100°C | 200°C | 260°C |
| A | DKIP-2 | 2.3 | 1.1 | 0.55 | 0.3 |
| B | DKIP-4 | 1.7 | 0.9 | 0.45 | 0.23 |
| C | DKIP-3, DKIP-5 | 1.5 | 0.7 | 0.35 | 0.2 |
| D | DKIP-1, DKIP-16* | 1 | 0.5 | 0.25 | 0.15 |
| F | DKIP-7 | 0.6 | 0.3 | 0.15 | 0.1 |
| G | DKIP-8, DKIP-9 | 0.4 | 0.2 | 0.1 | 0.05 |
* The source pressure table prints DKIP-16, while its dimensional table lists DKIP-1 through DKIP-9. Confirm the intended model before specifying the Group D rating. The printed 11/10 inch ID and 27.95 mm value are retained.
![]()
Six groups are shown: A, B, C, D, F and G. The vertical axis covers 0–2.5 MPa. Using fluids: air, water and inert gas. Material: PFA resin. Maximum operating temperature: 260°C. Use the pressure table for the relevant model and temperature.
Minimum Bending Data
The source index gives the following sequences. Column numbers preserve their printed order; they do not establish a model-by-model assignment.
| Metric index | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
| Recommended | 10 | 20 | 20 | 35 | 35 | 60 | 95 | 100 | 100 | 130 | 220 | 400 |
| Yield | 7 | 15 | 15 | 20 | 20 | 40 | 60 | 65 | 65 | 110 | 160 | 290 |
| Inch index | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 |
| Recommended | 10 | 20 | 20 | 35 | 35 | 60 | 95 | 100 | 100 | 130 | 160 | 220 | 400 |
| Yield | 7 | 15 | 15 | 20 | 20 | 40 | 60 | 65 | 65 | 110 | 130 | 160 | 290 |
Use a bending radius greater than the recommended value. Bending below it can cause tube damage. The yield value is described as twice the radius when folding or rupture occurs in the illustrated test; it is not a guaranteed service value.
![]()
Test method: at 20°C, bend the tube into a U shape, fix one end and gradually move the other end toward it. Measure 2R when the bent section’s outer-diameter deformation reaches 5%.
Fluid Use and Installation
Suitable fittings and fluids vary. For liquids, keep instantaneous impact pressure within the maximum operating pressure. Excess impact pressure may damage joints or rupture the tube. Abnormal temperature rise caused by adiabatic compression may also cause rupture.
Avoid shaking or vibrating conditions. Operating pressure must remain below the allowable tube and fitting limits. Long-term or high-temperature use can change the material and cause leakage; inspect and maintain the installation regularly.
Technical Specifications
- Physical & Chemical Properties of Fluororplastics
- SPECIFIC GRAVITY
- TECHNICAL NOTE for FLIUOROPOLYMER
Certificaciones
PFA(REACH)Certification
PFA(Rohs)Certification
PFA-FDA Certification
PFA-PFos Certification
PFA Tubing Certification
How to Select the Right PFA Tube
| Selection Step | What to Define |
| 1. Identify the Medium | Chemical, solvent, water, gas, reagent, process fluid or other conveyed medium. |
| 2. Define Purity Requirements | Determine whether standard industrial, clean, high-purity or application-specific material control is required. |
| 3. Define Temperature | Specify minimum, normal and maximum operating temperature, including short-term peaks. |
| 4. Define Pressure | Provide working pressure, peak pressure, pressure cycles and pulsation if applicable. |
| 5. Specify Dimensions | ID, OD and wall thickness determine flow, fit, mechanical behavior and pressure capability. |
| 6. Check Transparency Needs | If operators need to visually monitor flow, bubbles or contamination, transparent PFA may be advantageous. |
| 7. Check Flexibility / Routing | Consider bend radius, installation path, movement and whether a different construction is required. |
| 8. Confirm Compliance | State FDA, RoHS, REACH, USP Class VI or customer-specific requirements where applicable. |
| 9. Define Packaging | Specify coil length, straight-cut length, cleanliness, protective packaging, labeling and quantity. |
Custom PFA Tube Solutions
Provide the required ID, OD, wall thickness and tolerances, together with coil or straight-cut length. Small-bore, thin-wall and thick-wall constructions can be reviewed against tooling and production capability. Natural appearance, special configurations, OEM labeling and packaging can be specified for confirmation.
For high-purity applications, include material and process controls, cleanliness criteria, protective packaging and required reports. A drawing or sample helps define nonstandard geometry and connection requirements.
Temperature and Pressure Selection
Use the actual operating temperature when selecting the pressure rating. Include working and peak pressure, pulses, thermal cycles, fitting limits, routing, installation stress and unsupported spans. For higher-pressure service, request confirmation for the exact tube size and construction.
PFA PTFE and FEP Comparison
| Propiedad | PFA | PTFE | FEP |
| Resistencia química | Broad resistance; verify the exact medium | Broad resistance; verify the exact medium | Broad resistance; verify the exact medium |
| High-purity applications | Grade, processing and packaging dependent | Grade, processing and packaging dependent | Grade, processing and packaging dependent |
| Transparencia | Clear or translucent; grade dependent | Typically opaque or translucent | Clear or translucent; grade dependent |
| Melt processing | Melt processable | No conventional melt processing | Melt processable |
| Low adhesion | Fluoropolymer surface | Fluoropolymer surface | Fluoropolymer surface |
| Thermal service | Use size-specific temperature-pressure data | Confirm product-specific service limits | Confirm product-specific service limits |
| Typical selection focus | Transparent, demanding fluid paths | Chemical service, insulation and low friction | Transparent chemical tubing and fluid paths |
Choose the material against the medium, temperature, pressure, cleanliness and installation requirements. A general material comparison does not replace the specification of the finished tubing.
Manufacturing and Quality Control
Consistent tube performance depends on resin selection, extrusion, dimensional control and final inspection. For high-purity applications, process cleanliness and packaging are additional parts of the specification.
| Process | Quality Focus |
| Material Selection | Select PFA resin/grade according to purity, chemical, thermal, electrical and regulatory requirements. |
| Material Preparation | Condition and prepare material according to the selected extrusion process. |
| Extrusion | Control tooling, temperature and process parameters to establish stable tube geometry. |
| Sizing & Cooling | Control OD, ID and wall geometry during sizing and cooling. |
| Dimensional Inspection | Check ID, OD, wall thickness, length and appearance against the agreed specification. |
| Surface / Cleanliness Check | Evaluate surface condition and cleanliness requirements where the application demands them. |
| Cutting / Coiling | Supply controlled straight lengths or coils with suitable protective packaging. |
| Final Inspection | Verify dimensions, appearance, labeling, packaging and order-specific requirements before shipment. |
Why Choose Yozonetech?
| Yozonetech Advantage | Customer Value |
| Manufacturer Direct | Direct manufacturing supply for fluoropolymer tubing and related products. |
| Broad Fluoropolymer Range | PTFE, PFA, FEP, ETFE and PVDF tubing options support material selection across different applications. |
| Custom Dimensions | Application-specific ID, OD, wall thickness and length can be evaluated. |
| OEM / ODM Support | Suitable for customized industrial programs and repeat production requirements. |
| Application-Oriented Support | Technical discussion can be based on medium, purity, temperature, pressure, dimensions and compliance needs. |
| Documentation Support | Applicable technical and compliance documents can be provided according to the selected product and market. |
| Integrated Product Portfolio | PFA can be combined with PTFE/FEP tubing, heat-shrink tubing and reinforced hose solutions for broader system requirements. |
Documentation and Compliance Requirements
Tell us which technical reports, declarations or certificates your application requires. Food-contact documentation, RoHS, REACH, USP Class VI or other product-specific requirements must be confirmed for the exact grade and supplied tubing.
If your procurement system requires ISO 9001, ISO 14001, ISO 45001, IATF 16949 or another management-system certificate, identify the required standard and scope in the inquiry. Availability, validity and applicability must be confirmed with the quotation.
Request a PFA Tube Quote
| Information | Recommended Details |
| Required Dimensions | ID × OD or ID × wall thickness |
| Longitud | Coil length or straight-cut length |
| Medio | Chemical / gas / water / reagent / process fluid / other |
| Purity | Standard / clean / high-purity / customer-specific |
| Temperatura | Minimum / normal / maximum operating temperature |
| Pressure | Working pressure and peak pressure |
| Quantity | Sample / trial / batch / annual demand |
| Compliance | FDA / RoHS / REACH / USP Class VI / customer standard |
| Aplicación | Equipment, industry and installation conditions |
Send your dimensions or drawing and operating requirements so Yozonetech can review the appropriate grade, size and manufacturing specification. Confirm pricing, minimum order quantity, documentation and delivery timing against the agreed product.
Correo electrónico: ptfetube@yozonetech.cn
Website: www.chinaptfetube.com
Preguntas frecuentes
1 How do I choose the right PFA tubing size
Specify the required outer diameter (OD) and inner diameter (ID), together with your fitting dimensions and flow requirements. Send us your existing tube specification or equipment drawing, and we can review the corresponding metric or inch option before quotation.
2 Can I order both metric and inch PFA tubing
Yes. Our listed range includes 13 metric sizes and nine inch models. Provide the exact OD and ID rather than relying only on the nominal size, so we can confirm the tubing matches your connections.
3 Can you supply a size that is not listed
Send your required OD, ID, tolerances, length and quantity. We will review production feasibility and confirm availability, minimum order quantity and lead time for the requested size.
4 What working pressure should I specify
Provide your normal and maximum pressure, operating temperature and fitting details. The permitted pressure varies by tube size and temperature. We can review the relevant pressure group and identify any specifications that need confirmation before you order.
5 Can PFA tubing operate at 260°C
The listed maximum operating temperature is 260°C, with reduced pressure limits at elevated temperatures. Tell us your temperature, pressure and exposure duration so we can review the proposed tube and connection requirements together.
6 Is this PFA tubing suitable for my process fluid
The operating index lists air, water and inert gas. For other media, send the chemical name, concentration, temperature and cleaning agents. We can review the material requirements and identify whether additional compatibility evidence is needed.
7 What lengths can I order
The metric and inch series tables specify 100 m lengths. If you need another roll length or cut pieces, include the required length and tolerance in your inquiry. We will confirm the available supply format for your selected size.
8 Can I request samples before placing a production order
Yes. Contact us with the size, quantity and intended evaluation. We will confirm sample availability, pricing and delivery details so you can assess fitting compatibility and installation before committing to a larger order.
9 What inspection records or material documents can you provide
State which documents you require, such as material identification, dimensional inspection results or application-specific test reports. We will confirm the available documentation and any additional inspection scope with the quotation.
10 How can I get an accurate quotation and delivery estimate
Send the OD × ID or model number, required length, quantity, tolerances and delivery destination. Include the operating medium, temperature, pressure and documentation requirements. With these details, we can confirm the proposed specification, price, minimum order quantity and lead time.
+86-13752771911
E-mail:ptfetube@yozonetech.cn








Certification-1.webp)