wiring insulation

  • Raucharm, halogenfrei, flammhemmend, feuerbeständig Wirez&cable

    Raucharmes, halogenfreies, flammhemmendes, feuerbeständiges Wirez&cable

    Electric Wire Insulation Produkt-Spezifikation

    Working temperature: -50℃~+200℃

    Extrudiertes Kunststoffrohr Color: Black

    Tensile strength: >8.2MPa

    Elongation at break: >200%

    Voltage resistance: 85KV

    Usage: This insulated wires mainly provides insulation protection for wires and cables of household appliances and industrial machinery.

    Cutting tools: Cutting machine, scissors

    Zertifizierung: ROHS

    PDF:Low-smoke No(low)-halogen Flame Retardatory Fire Resistance Wire & cable

  • XLPE-isolierte elektrische Kabel

    XLPE-isolierte elektrische Kabel

    1. Electric Cable Insulation​ Usage

    The cable is used in electric transmission and distribution system operation at rated voltage of 0. 6/1, 1. 8/3, 3. 6/6, 6/6, 6/10,8. 7/10,8.7/15,12/20,21/35,26/35KV

    2. Electric Cable Insulation​  Model and name

    Mold name
    YJV
    YJLV
    Cu or AI conductor. XLPE insulated. PVC sheathed electric cable
    YJV22
    YJV22
    Cu or AI conductor, XLPE insulated steel tape armored PVC sheathed electric cable
    YJV32.42
    YJV32.42
    Cu or AI conductor, XLPE insulated steel tape armored PVC sheathed electric cable

    3. Electric Cable Insulation​ Technology property

    1. Bending radius:

    Bending radius of single core cable is 20 (d+D) ±5%

    Bending radius of multi-core cable is 15 (d+D) ±5%

    D=Actual outer diameter of cable sample (mm )

    d=Actua1 diameter of the conductor (mm )

    2. Installation temperature:

    Insulated wires should be heated where ambient temperature is below 0'C

    3. Lever difference of cable installation:

    Silicone tube suppliers Not restricted by the difference of level along the route.

    PDF:XLPE-isolierte elektrische Kabel

  • PVC-isolierter Draht (JB8734-2012)

    PVC-isolierter Draht (JB8734-2012)

    1. Wire Insulation Usage

    This insulated wires product is fit for ac rated voltage 450/750V.

    2. Wire InsulationWorking temperature

    BV-105 Model not more than 105C. other not more than 70°C installation temperature not lower than 0°C.

    3. Wire Insulation Performance

    1 ) Finished insulation core and finished power line are put into the water at the temperature 20 + SC for an hours. they should be able to experience the

    AC voltage testing.

    2) Outer power line is good at insulation property. machines property and non-inflammability with reliable quality and convenient durability.

    3) Extrudierte Kunststoffrohre finished power line should have products name, model and voltage signs.

    PDF:PVC-isolierter Draht (JB8734-2012)

  • Raucharmes, halogenfreies, flammhemmendes, feuerfestes Kabel und Draht

    Raucharmes, halogenfreies, flammhemmendes, feuerfestes Kabel und Draht

    1. Electrical Cable Insulation Brief product introduction

    Low smoke (low) halogen-free cables and wires produce very small amount of smoke in the case of flame combustion. The released gas contains no halogen (low

    halogen) elements and is non-toxic (low toxicity). When a fire occurs, it can greatly reduce the hazards to low-altitude devices, equipment and human body.

    Therefore, it is widely used in high-rise buildings, hospitals, large libraries, gymnasiums, Disaster Prevention Command and control buildings, stations and civil

    airports, passenger waiting rooms, key cultural relies protection sites and subway, underground shopping malls or densely populated public places.

    Unser silicone tube suppliers develops and produces plastic insulated cables and wires with rated voltage of 35KV and below. Their performance not only meets the requirements

    of CB/T12706-2008, GB/T5023-2008 and GB9330-88, DGJ08-93-2002, but also forms a series of flame-retardant and fire-resistant types, especially low smoke and

    halogen-free (low halogen) performances, which meet the national standards GR/T17652-1-21998, GB/17651.1-2-1998, and has been certified by national first-level

    science and technology. Certainly, this kind of insulated wires has reached the domestic advanced level of similar products.

    2.Electrical Cable Insulation Grade and choose for the using location

    Low smoke and no. (low) halogen use places should be classified as Grade 1, Grade 2, Grade 3 according to the use nature of buildings, fire risk, evacuation and rescue difficulty.

    2. Flame-retardant wires and cables should be used when low smoky (low) halogen-free wires and cables are bound. The selection of flame-retardant grade should be in accordance with Table 2 and Table

    3. Under the action of external fire, fire-resistant wires and cables should be used to maintain the integrity of the lines and maintain the power supply.

    PDF:Low-smoke No(low)-halogen Flame Retardatory Fire Resistance Wirez&cable

1Seite 1 / 1